检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Chun-Hai Bai Jian-Ning Fu Tao-Ran Li Zhou Fan Jiang-Hua Wu Yong Zhao Xian-Qun Zeng Wen-Zhao Zhang Peng Qiu Guo-Jie Feng Xiao-Jun Jiang
机构地区:[1]National Astronomical Observatories,Chinese Academy of Sciences,Beijing 100101,China [2]University of Chinese Academy of Sciences,Beijing 100049,China [3]Xinjiang Astronomical Observatory,Chinese Academy of Sciences,Urumqi 830011,China [4]Department of Astronomy,Beijing Normal University,Beijing 100875,China
出 处:《Research in Astronomy and Astrophysics》2018年第9期21-30,共10页天文和天体物理学研究(英文版)
基 金:support from the staff at the Xinglong 85-cm telescope;support from the National Natural Science Foundation of China(NSFC)through grant 11673003;the National Basic Research Program of China(973 program,2014CB845700);partially supported by the Open Project Program of the Key Laboratory of Optical Astronomy(National Astronomical Observatories);NSFC under Grant Nos.11403088 and 11273051(Xinjiang Astronomical Observatory);Chinese Academy of Sciences and Department of Astronomy,Beijing Normal University
摘 要:The 85-cm telescope at Xinglong station is a prime focus system that operates well with high science outputs. The telescope has been upgraded since 2014 with a new corrector, and new filters and camera, which are provided by Beijing Normal University. The filter set is the Johnson-Cousins UBV RI system. We report the test results of the new system including bias, dark current, linearity, gain and readout noise of the CCD camera. Then we derive accurate instrumental calibration coefficients in UBV RI bands with Landolt standard stars during photometric nights. Finally, we give the limiting magnitudes with various exposure times and signal-to-noise ratios for observers as references.The 85-cm telescope at Xinglong station is a prime focus system that operates well with high science outputs. The telescope has been upgraded since 2014 with a new corrector, and new filters and camera, which are provided by Beijing Normal University. The filter set is the Johnson-Cousins UBV RI system. We report the test results of the new system including bias, dark current, linearity, gain and readout noise of the CCD camera. Then we derive accurate instrumental calibration coefficients in UBV RI bands with Landolt standard stars during photometric nights. Finally, we give the limiting magnitudes with various exposure times and signal-to-noise ratios for observers as references.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.189.141.66