检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:朱妍[1] ZHU Yan(Taixi Coal Preparation Plant,Shenhua Ningxia Coal Mining Group Corporation Ltd.,Yinchuan 753000,China)
机构地区:[1]神华宁夏煤业集团有限责任公司太西洗煤厂,宁夏银川753000
出 处:《煤质技术》2018年第5期38-41,47,共5页Coal Quality Technology
摘 要:以HD型全自动显微光度计测定煤的镜质体反射率为例,阐述了采用显微光度计测定镜质体反射率的测定原理、测定步骤、样品制备及煤岩制片过程,并从仪器质量及安装调试、试验室温度、标准片质量等方面分析影响测定结果准确性的因素。通过对实验过程和异常数据检测结果的对比分析表明,在冷凝法制片过程中配制不饱和聚酯树脂时,促进剂对煤的镜质体反射率测定结果有决定性的影响。建议在过程管理中细化实验标准,重点把控煤砖片制备过程中固化剂和促进剂的精准控量。Taking the HD fully automatic microphotometer to determine the reflectance of vitrinite of coal, this paper demonstrated the determination principles, testing procedure, sample preparation, coal petrography preparation of using microphotometer to determine the reflectance of vitrinite, and from aspects such as instrument quality and installation and commissioning, laboratory temperaturc, standard sample quality, the elements which affected the accuracy of determination results were analyzed. Throughcomparison analysis of abnormal data detection result in theprocess, it was showed that, during the preparation of unsaturated polyester resin in the condensation method sample preparation, the accelerator has decisive influence for reflectance ofvitrinitedetcrmination results, it was suggested that the experimentalstandard should be refined in the process, management, the precise control of curing agent and accelerator in the preparation of polished blocks could be achieved.
关 键 词:促进剂 镜质体反射率 显微光度计 煤岩制备 冷凝法制片 煤砖光片 固化剂 影响因素 不饱和聚酯树脂
分 类 号:TQ533[化学工程—煤化学工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.171