机构地区:[1]National Key Laboratory of Science and Technology on Aero-Engine Aerothermodynamics, Collaborative Innovation Center for Advanced Aero-Engine [2]School of Energy and Power Engineering, Beihang University [3]Department of Mechanical Engineering and Materials Science, Duke University
出 处:《Chinese Journal of Aeronautics》2018年第7期1470-1479,共10页中国航空学报(英文版)
基 金:the supports of the National Natural Science Foundation of China (Nos.51636001 and 51706008);Aeronautics Power Foundation of China (No.6141B090315);China Postdoctoral Science Foundation (No.2017M610742)
摘 要:Previous studies showed that an axisymmetric hub-initiated disturbance defined as partial surge may initiate the stall of a transonic compressor; to reveal the instability evolution under full-span incompressible flow for different levels of hub loading and B parameter, an experimental investigation is conducted on a single-stage low-speed compressor. Experimental results show that under a uniform inflow condition without inlet flow distortion, a modal-type stall inception dominates in this low-speed compressor. When an inlet screen introducing hub distortion is used to increase the hub loading, a compressor stall is initiated by a modal wave, but large disturbances are present in the hub region before the compressor stall, which become stronger as the hub loading increases. Under high hub loading and large B parameter(implemented by adding hub distortion through an inlet screen and enlarging the outlet plenum volume, respectively), a compressor stall is triggered by an axisymmetric hub-initiated disturbance, which is much different from the modal-like disturbances. The beginning of this axisymmetric disturbance may be captured over 800 rotor revolutions prior to the onset of stall, and the amplitude grows with time. The disturbance is hub-initiated because the disturbance signal at the hub is detected much earlier than that at the tip; meanwhile, the frequency of this axisymmetric disturbance changes with the length of the inlet duct. The characteristics of instability evolution in the low-speed compressor are also compared with those in a transonic compressor.Previous studies showed that an axisymmetric hub-initiated disturbance defined as partial surge may initiate the stall of a transonic compressor; to reveal the instability evolution under full-span incompressible flow for different levels of hub loading and B parameter, an experimental investigation is conducted on a single-stage low-speed compressor. Experimental results show that under a uniform inflow condition without inlet flow distortion, a modal-type stall inception dominates in this low-speed compressor. When an inlet screen introducing hub distortion is used to increase the hub loading, a compressor stall is initiated by a modal wave, but large disturbances are present in the hub region before the compressor stall, which become stronger as the hub loading increases. Under high hub loading and large B parameter(implemented by adding hub distortion through an inlet screen and enlarging the outlet plenum volume, respectively), a compressor stall is triggered by an axisymmetric hub-initiated disturbance, which is much different from the modal-like disturbances. The beginning of this axisymmetric disturbance may be captured over 800 rotor revolutions prior to the onset of stall, and the amplitude grows with time. The disturbance is hub-initiated because the disturbance signal at the hub is detected much earlier than that at the tip; meanwhile, the frequency of this axisymmetric disturbance changes with the length of the inlet duct. The characteristics of instability evolution in the low-speed compressor are also compared with those in a transonic compressor.
关 键 词:Axisymmetric disturbance B parameter Flow instability Low-speed axial compressor Radial blade loading distribution
分 类 号:V231[航空宇航科学与技术—航空宇航推进理论与工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...