严寒地区超低能耗建筑与节能65%建筑能耗模拟对比分析  被引量:2

The Energy Consumption Analysis of a Super Energy Saving Building in Severe Cold Zone Comparing with the Building with 65% Energy Saving Efficiency

在线阅读下载全文

作  者:王杨洋[1] 崔正旭[1] 陶进[1] WANG Yang-yang, CUI Zheng-xu, TAO Jin(Municipal and Environmental Engineering Insitute, Changchun 13 0114,China)

机构地区:[1]吉林建筑大学城建学院,长春130114

出  处:《工程建设与设计》2018年第21期20-21,24,共3页Construction & Design for Engineering

基  金:住建部2015年低能耗建筑示范工程(2015S1B-002);吉林省重点科技攻关项目(20170204023SF)严寒地区超低能耗建筑的研究与示范

摘  要:为进一步提高严寒地区建筑节能潜力,对吉林省某超低能耗建筑进行能耗分析.该超低能耗建筑集毛细管辐射供暖/供冷系统,地源热泵系统,全热回收新风系统,太阳能光热系统等多项节能技术.利用eQUEST软件模拟分析超低能耗建筑能耗,与DB 22/T450-2007《吉林省《居住建筑节能设计标准(节能65%)》参照建筑进行对比分析,全年总能耗节能72.7%,尤其是采暖能耗能节能96.7%,结果表明严寒地区超低能耗建筑节能效果显著.In order to further improve toe energy saving potentiao ofbuioding in severe cood zoneo a super energy saving building in Jilin province is elected to research on energy consumption analysis. This super energy saving building integrates various energy efficiency technologies, including the capillary radiation heating/cooling system, ground-source heat pump system, fresh-air total heat recovery system and solar heating system. The energy consumption of the super energy saving building is simulated and analyzed byeQUESTsoowareoacoordingtotoeDesignStandardforEnergyEfociencyofResidentialBuiodings (Energy Efficiency 65%) in Jilin Province (DB22/T450-2007), the super energy saving building will save 72.7% energy the whole year ,especially the energy consumption of heating can be saved by 96.7% comparing with the same type of energy efficiency 65% building. This proves that the energy efficiency of super energy saving building in severe cold zone is remarkable.

关 键 词:严寒地区 超低能耗建筑 能耗分析 节能 

分 类 号:TU201.5[建筑科学—建筑设计及理论]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象