300MW循环流化床锅炉炉内管屏变形的原因及分析  被引量:4

The analysis and causes of platen heaters deformation in 300MW CFB boiler furnace

在线阅读下载全文

作  者:郎丽萍[1,2] 郭建明[1,2] 侯学伟[1] Lang Liping;Guo Jianming;Hou Xuewei(Harbin Boiler Company Limited,Harbin 150046,China;State Key Laboratory of Efficient and Clean Coal-fired Utility Boilers(Harbin Boiler Company Limited.),Harbin 150046,China)

机构地区:[1]哈尔滨锅炉厂有限责任公司,黑龙江哈尔滨150046 [2]高效清洁燃煤电站锅炉国家重点实验室(哈尔滨锅炉厂有限责任公司),黑龙江哈尔滨150046

出  处:《锅炉制造》2018年第6期10-12,共3页Boiler Manufacturing

摘  要:随着CFB锅炉大型化发展,炉内增加了屏式过热器、屏式再热器及水冷屏等屏式受热面,但在实际运行中存在着管屏变形及爆管等问题,影响机组的安全稳定运行。通过对管屏变形原因的分析,提出了解决管屏变形的措施,优化了整体结构,提高了运行的可靠性。With the development of water-cooled platen are arranged large -scale CFB boiler, platen superheater,platen reheater and in furnace. Platen heaters deformation and tube explosion prob- lems existed in the actual motion affect the safe and stable operation of boiler. By analyzing the reason of platen heaters deformation, putting forward some measures to solve platen heaters deformation and tube explosion problems, which optimize boiler overall structure and improve operational stability.

关 键 词:循环流化床锅炉 屏式受热面 管屏变形 壁温偏差 炉顶密封 

分 类 号:TK224[动力工程及工程热物理—动力机械及工程]

 