两种硬质三维成形环用于功能性三尖瓣反流的效果比较  

Effect Comparison of Two Types of Rigid Three-dimensional Annuloplasty Rings in Application of Surgery for Functional Tricuspid Regurgitation

在线阅读下载全文

作  者:赵亮[1] 彭晓波[2] 陈劲进[2] 翟建宾[1] 范子盼 肖颖彬[2] ZHAO Liang;PENG Xiao-bo;CHEN Jin-jin;ZHAI Jian-bin;FAN Zi-pan;XIAO Ying-bin(Department of Cardiothoracic Surgery,Bethune International Peace Hospital of PLA,Shijiazhuang 050082,China;Department of Cardiovascular surgery,the Second Affiliated Hospital of the Third Military Medical University,Chongqing 400037,China)

机构地区:[1]解放军白求恩国际和平医院心胸外科,石家庄050082 [2]第三军医大学第二附属医院心外科,重庆400037

出  处:《解放军医药杂志》2018年第11期51-54,共4页Medical & Pharmaceutical Journal of Chinese People’s Liberation Army

基  金:河北省医学科学研究重点课题计划(20150006)

摘  要:目的观察佰仁思和爱德华MC3硬质三维成形环用于功能性三尖瓣反流(FTR)的治疗效果。方法选取2015年9月—2016年6月在解放军白求恩国际和平医院确诊的左心瓣膜疾病合并中度FTR 42例,按照应用三维成形环不同分为佰仁思组和爱德华组,每组21例。佰仁思组采用佰仁思三维成形环治疗;爱德华组采用爱德华硬质三维成形环治疗,观察并比较2组的手术效果、右心室前后径、肺动脉压力及并发症发生情况。结果 2组均无围手术期死亡。2组术后三尖瓣反流较术前明显降低(P <0. 05),但组间比较差异无统计学意义(P> 0. 05)。2组术后右心室直径及肺动脉压力均低于术前(P <0. 05),但组间比较差异均无统计学意义(P> 0. 05)。结论国产佰仁思三维成形环和进口爱德华MC3硬质三维成形环用于左心瓣膜病合并中度FTR效果相当,国产佰仁思硬质三维成形环值得临床推广。Objective To observe effects of Balmedic and Edward MC3 rigid three-dimensional (3-D) annuloplasty rings in application of surgery for functional tricuspid regurgitation (FTR). Methods A total of 42 patients with left heart valve disease combined with moderate FTR admitted during September 2015 and June 2016 were divided into Balmedic and Edward groups ( n =21 in each group) according to types of 3-D annuloplasty rings. Balmedic group was treated with Balmedic rigid 3-D annuloplasty ring, and Edward group was treated with Edward rigid 3-D annuloplasty ring. Surgical effects, anteroposterior diameter of right ventricle, pulmonary arterial pressure and incidence rate of complications were observed and compared in two groups. Results There were no deaths during peroperative period in two groups. Degrees of FTR after surgery were significantly decreased compared with those before surgery in two groups ( P 〈0.05), but the difference between two groups was not statistically significant ( P 〉0.05). Values of anteroposterior diameter of right ventricle and pulmonary arterial pressure after surgery were significantly lower than those before surgery in two groups ( P 〈0.05), but the differences between two groups were not statistically significant ( P 〉0.05). Conclusion Domestic Balmedic and overseas Edward MC3 rigid 3-D annuloplasty rings may achieve similar clinical effects in the treatment of patients with left heart valve disease combined with moderate FTR.

关 键 词:三尖瓣闭锁不全 三尖瓣成形环术 爱德华MC3 佰仁思 

分 类 号:R654.2[医药卫生—外科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象