三维测头耦合分析与校正  被引量:2

Coupling Analysis and Calibration of 3D Probe

在线阅读下载全文

作  者:郭强[1] 黄强先[1] 吴奎[1] 陈丽娟[1] 李瑞君[1] 李红莉[1] Guo Qiang;Huang Qiangxian;Wu Kui;Chen Lijuan;Li Ruijun;Li Hongli

机构地区:[1]合肥工业大学

出  处:《工具技术》2018年第11期152-155,共4页Tool Engineering

基  金:科技部863计划(2008AA042409);合肥工业大学教学研究资助项目(2016YQJY0103)

摘  要:基于微型迈克尔逊干涉原理和激光自准直原理构成的三维接触扫描测头,从机械结构误差分析了测头输出三路信号产生耦合的原因。为减小信号耦合对测量结果的影响,通过微纳米测量机三维定位工作台对测头三个坐标轴方向进行标定,最终采用四次多项式模型建立工作台位移和测头输出信号之间的关系。信号处理基于Labview软件实现,计算结果表明该模型误差在±30nm以内。Described a three-dimensional contact scanning probe which based on the principle of micro-Michelson in- terference and laser autocollimator, the coupling of three axes is analyzed from mechanical structure error. In order to reduce the impact of signal coupling on the measurement, the three-dimensional positioning table of the measuring machine is used to calibrate the three directions of the touch trigger probe. The quadratic polynomial model is used to establish the relation- ship between the worktable displacement and the probe output signal. The signal processing realized based on Labview soft- ware, the calculation results show that the error of the model is within ±30nm.

关 键 词:触发测头 机械机构 耦合分析 坐标测量机 测头标定 校正 

分 类 号:TG801[金属学及工艺—公差测量技术] TH822[机械工程—仪器科学与技术]

 