检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:徐豪杰 高山[1] 任艳丽[1] 荣守华[2] XU Hao-jie;GAO ShanI;REN Yan-li;RONG Shou-hua(Department of Pharmacy,The Third Affiliated Hospital,Zhengzhou University,Zhengzhou 450052,China;Department of Clinieal Laboratory,The Third Affiliated Hospital,Zhengzhou University,Zhengzhou,450052,China)
机构地区:[1]郑州大学第三附属医院药学部,郑州450052 [2]郑州大学第三附属医院检验科,郑州450052
出 处:《药物分析杂志》2018年第11期1994-1999,共6页Chinese Journal of Pharmaceutical Analysis
基 金:河南省教育厅基金资助项目(17A350015)
摘 要:目的:建立酪氨酸对映体的柱前手性衍生高效液相色谱-化学发光联用新方法,并用于体内外酪氨酸对映体的高效检测。方法:利用柱前手性衍生高效液相色谱法对酪氨酸对映体进行分离,联用化学发光检测器对酪氨酸对映体进行检测。考察了色谱流动相配比、流速、柱温以及化学发光条件对酪氨酸对映体分离结果的影响。采用柱前手性衍生高效液相色谱-化学发光联用法对生物样品中的酪氨酸对映体进行分离分析。结果:最佳色谱条件下,流动相为甲醇-0.01 mol·L^(-1)磷酸二氢钾溶液(35∶65,p H 6.0),流速为0.7 mL·min^(-1),柱温为室温;最优化学发光体系为氢氧化钠、鲁米诺和高锰酸钾,其浓度分别为0.15、4.0×10^(-5)和4.0×10^(-5) mol·L^(-1)。在此优化条件下,酪氨酸对映体可以达到完全分离(RS>2.0),线性检测范围为2.5×10^(-7)~3.2×10^(-5) g·m L^(-1),L-/D-酪氨酸的检测下限分别为2.96×10^(-8)、3.59×10^(-8) g·m L^(-1)。结论:柱前手性衍生高效液相色谱-化学发光联用法可对酪氨酸对映体进行高选择性、高灵敏度检测。Objective:To establish a novel HPLC-CL method with precolumn chiral derivatization for the determine of tyrosine enantiomers,and to detect chiral substances in vivo and in vitro.Methods:The tyrosine enantiomers were separated by HPLC with precolumn chiral derivatization and detected by chemiluminescence detector;the chromatographic mobile phase,flow rate,column temperature and chemiluminescence conditions were investigated;the established method was used to analyze the tyrosine enantiomers in biological samples.Results:The chromatographic mobile phase consisted of methanol and 0.01 mol·L-1 monopotassium phosphate solution(35∶65,pH 6.0),the flow rate was 0.7 mL·min-1,and the column temperature was room temperature.The chemiluminescence system was composed of sodium hydroxide(0.15 mol·L-1),luminol(4.0×10-5 mol·L-1)and potassium permanganate(4.0×10-5 mol·L-1).Under the optimized conditions,the tyrosine enantiomers could be completely separated(RS2.0)with the linear range of 2.5×10-7 ~3.2×10-5 g·mL-1,and the detection limits of L-and D-tyrosine were 2.96×10-8 and 3.59×10-8 g·mL-1,respectively.Conclusion:The established method can be used to selectively and sensitively determine tyrosine enantiomers.
关 键 词:柱前衍生化 手性色谱法 化学发光法 酪氨酸对映体 高灵敏
分 类 号:R917[医药卫生—药物分析学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117