摘  要:随着微机监测系统在信号设备维护中的运用越来越深入,系统功能越来越完善,维护人员对设备运行状态的掌握越来越准确和全面。信号维护人员在设备维护中要充分利用微机监测的各项监测数据、曲线来分析设备运行状态,并结合设备电路结构、器材特性来指导设备维修和故障处理。本文对利用微机监测数据判断处理XSLE型LED信号机故障进行了分析,介绍了故障分析判断的方法。With the further application of microcomputer monitoring system in the maintenance of signal equipment, the function of the system is becoming more and more perfect, and the maintenance personnel have more and more accurate and comprehensive grasp of the operating state of the equipment. The signal maintainers should make full use of the monitoring data and curves of microcomputer to analyze the running state of the equipment in equipment maintenance, and combine the circuit structure and the characteristics of the equipment to guide the maintenance and fault treatment of the equipment. In this paper, the fault of XSLE type LED semaphore is analyzed and the method of fault analysis and judgment is introduced.

关 键 词:微机监测 点灯电流 LED信号机 故障分析 

分 类 号:U2[交通运输工程—道路与铁道工程]

 