检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]延边大学理工学院电子信息工程系,吉林延吉133002
出 处:《延边大学学报(自然科学版)》2002年第3期197-199,共3页Journal of Yanbian University(Natural Science Edition)
摘 要:论述了利用变频器、压力传感器、可编程序控制器以及自制的控制器组成的改进型消防恒压供水控制系统 .此系统具有自动定期检查消防泵能否正常工作、系统是否漏水、系统是否有人操作等功能 ,并且当火灾发生时可自动起动消防泵 。This thesis discusses improved water supply control system with constant pressure in the fire fighting that is composed of transducer, pressure sensor, PLC as well as homemade controller. This system possesses the function that can automatically time examine whether the fire engine works normally, whether the system leakes water, whether the system is operated by anyone. Furthermore, the system possesses the function that can automatically start up fire engine when fire happens and overcome the status operated manually or depended on fire sensor formerly.
关 键 词:消防供水控制系统 定期检查 漏水检查 判断故障 自动起动 系统结构 消防泵 系统设计
分 类 号:TU998.13[建筑科学—市政工程] TP273[自动化与计算机技术—检测技术与自动化装置]