检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:栗再新[1] 冯开明[1] 张国书[1] 郑国尧 赵奉超[1]
出 处:《原子能科学技术》2009年第S2期223-226,共4页Atomic Energy Science and Technology
基 金:国家重点基础研究发展计划资助项目(2009GB108000)
摘 要:氦气、水、熔盐(Flibe)在强磁场中流动不存在严重的MHD问题,因此适合在基于磁约束的聚变-裂变混合堆中作为冷却剂。针对氦气、水、Flibe这3种冷却剂对混合堆包层中子学性能的影响进行研究,分析包层中能谱特点及燃料增殖特性。通过燃耗计算,研究氚增殖率(TBR)、能量倍增因子(M)、keff等随运行时间的变化。中子学输运采用三维蒙特卡罗程序MCNP。计算结果表明,不同的冷却剂对混合堆系统中子能谱影响很大:氦冷系统的能谱最硬,主要发生快中子裂变,氚增殖效果最好;水冷系统的能谱最软,产能最多,但需提高TBR;Flibe冷系统的能谱较硬,产能最少。There is no serious magnetohydrodynamics (MHD) problem when helium, water or molten salt of Flibe flows in high magnetic field. Thus helium, water and Flibe were proposed as candidate of coolant for fusion-fission hybrid reactor based on magnetic confinement. The effect on neutronics of hybrid reactor due to coolant was investigated. The analyses of neutron spectra and fuel breeding of blanket with different coolants were performed. Variations of tritium breeding ratio (TBR), blanket energy multiplication (M) and keff with operating time were also studied. MCNP code was used for neutron transport simulation. It is shown that spectra change greatly with different coolants. The blanket with helium exhibits very hard spectrum and good tritium breeding ability. And fission reactions are mainly from fast neutron. The blanket with water has soft spectrum and high energy multiplication factor. However, it needs to improve TBR. The blanket with Flibe has hard spectrum and less energy release.
分 类 号:TL64[核科学技术—核技术及应用]