硫氰酸钨(V)络合物稳定常数的测定  

DETERMINATION THE STABILITY CONSTANT OF TUNGSTEN(V) -POTASSIUM THIOCYANATE COMPLEX

在线阅读下载全文

作  者:梁玉珍[1] 尹秀华[2] 武继芬[3] 

机构地区:[1]齐齐哈尔大学,齐齐哈尔610006 [2]上海市松江二中,上海201600 [3]山东轻工业学院,济南250100

出  处:《化学分析计量》2002年第5期36-38,共3页Chemical Analysis And Meterage

摘  要:测定了水溶液中硫氰酸钨(Ⅴ)络合物的吸收光谱,最大吸收波长为405 nm.在盐酸浓度为3.56 mol/L、离子强度为0.088 mol/L的溶液中,硫氰酸钾溶液浓度在0.018~0.088 mol/L范围内,与硫氰酸钨(Ⅴ)络合物的平均摩尔吸光系数△-ε呈函数关系.测得络合物的络合比为1:4.计算出络合物的各级累积稳定常数和摩尔吸光系数分别为:β1=40.73,β2=1.10×103,β3=2.40×104,β4=4.16×105,Δε1=9.33×103,Δε2=9.64×103,Δε3=9.93×103,Δε4=1.10×104(t=17.7℃).The absorption spectra of tungsten(V)-thiocyanate was determined in the water solution, in which λmax was 405 nm. In the solution condition of [H+] =3.56 mol/L and I=0.088 mol/L ,△εis a function of [KSCN] when [KSCN] is 0.018-0.088 mol/L. The complex ometric proportion determined is 1:4. The stability constants determined are β1 =40. 73 ,β2= 1. 10×103, β3=2. 40×104 ,β4=4. 16×105 respectively and the molar extinction coefficients are △δ1=9. 33×103, △δ2=9. 64×103, △δ3= 9. 93×103,△δ4= 1. 10×104(t=17.7℃) respectively.

关 键 词:络合物 稳定常数 测定 硫氰酸钨 络合比 摩尔吸光系数 吸收光谱 光度法 

分 类 号:O614.613[理学—无机化学] O657.3[理学—化学]

 