检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:宋微浪[1] 黄雄涛 谢雍 胡晓骏 SONG Wei-lang;HUANG Xiong-tao;XIE Yong-shen;HU Xiao-jun(Maintenance Branch Company of Fujian Electric Power Co., Ltd, Fuzhou 350013, China;Fuzhou Power Supply Company of Fujian Electric Power Co., Ltd, Fuzhou 350009, China)
机构地区:[1]国网福建省电力有限公司检修分公司,福建福州350013 [2]国网福建省电力有限公司福州供电公司,福建福州350009
出 处:《电工电气》2016年第12期45-47,共3页Electrotechnics Electric
摘 要:对一起超高压复合式绝缘组合电器(HGIS)断路器机构漏油事件进行分析,拆开相关储能模块及导向套进行检查,发现事故是由储能缸与工作缸对接的导向套在向缸孔引入时装配不当及所用密封圈、挡圈材质不佳引起,经过对相关密封圈、挡圈进行更换,消除了此起设备缺陷,并从日常维护及设计安装两方面提出断路器漏油防范措施。Analysis was made to a circuit breaker mechanism oil leakage fault in hybrid gas insulated switchgear (HGIS). The relevant energy storage module and guide sleeve were separated and inspected to find that the guide sleeve butted the energy storage cylinder to the working cylinder was assembled improperly when introduced to the cylinder hole and the quality of used seal ring and retainer ring was not good. After the relevant seal ring and retainer ring were changed, equipment defect was eliminated. This paper proposed the precautionary measures of circuit breaker oil leakage from two aspects of routine maintenance and design installation.
正在载入数据...