感应滤波技术在地铁牵引供电系统中的应用  被引量:4

Application of Inductive Filtering Technology in Traction Power System for Metro

在线阅读下载全文

作  者:陈程[1] 彭华厦[1] 曾进辉[1] CHEN Cheng;PENG Hua-xia;ZENG Jin-hui(College of Electrial and Information Engineering, Hunan University of Technology, Hunan Zhuzhou 412007, China)

机构地区:[1]湖南工业大学电气与信息工程学院,湖南株洲412007

出  处:《新型工业化》2016年第7期9-16,共8页The Journal of New Industrialization

基  金:湖南省自然科学基金项目(2016JJ5038)

摘  要:地铁供电系统存在谐波污染和功率因素偏低,损耗大等问题。为了解决这些问题,本文设计了一种基于感应滤波技术的新型地铁供电系统方案。新系统可以使得阀侧谐波无法通过整流变压器流入高压网侧,具有良好的谐波抑制和无功补偿效果。仿真结果验证了方案的有效性。There are many problems in the traction power supply system for metro, such as harmonic pollution, low power factor and great power loss. Thus, this paper designs a new traction power supply system based on inductive filtering technology for metro. The new system prevents harmonic currents from injecting into the primary winding through rectifier transformer.Simulation results prove the effectiveness of the proposed design.

关 键 词:地铁 牵引供电 感应滤波 谐波 

分 类 号:TM46[电气工程—电器]

 