检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:祝远寒 靳世平[1] 曾浩[1] ZHU Yuanhan;JIN Shiping;ZENG Hao(School of Energy Resources, Huazhong University of Science and Technology, Wuhan 430074, China)
机构地区:[1]华中科技大学能源与动力工程学院,湖北武汉430074
出 处:《工业加热》2016年第5期34-37,共4页Industrial Heating
摘 要:对步进式加热炉的散热损失进行了理论计算和数值模拟分析,通过选取工况较为复杂、分布较多烧嘴的炉顶均热段作为研究对象,模拟数据与实测数据误差为5%以内,表明了计算方法的可靠性与准确性,并以此为基础对加热炉炉体进行散热损失的计算,计算结果表明:炉顶的散热损失占炉体总散热损失的58.21%,大于炉墙和炉底散热量总和,表明炉顶具有更大的节能潜力。This article is to analyze the heat loss of walking beam reheating furnace by the means of theoretical computation and numerical simulation, because of soaking zone have a lot of burners and the condition is complex, so we select it as subject in the study.The deviation between simulated and measured data is less than 5%, it means reliability and accuracy of theoretical computation. On the basis of the computation, we calculate the heat loss of the furnace.The result shows that the furnace top^ heat loss accounted for 58.21% of total heat loss, and it is greater than the sum of furnace wall or bottom, it means the furnace top has greater energy saving potential.
分 类 号:TG155.12[金属学及工艺—热处理]