检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李国庆[1] 孙银锋[2] 吴学光 Li Guoqing;Sun Yinfeng;Wu Xueguang(School of Electrical Engineering Northeast Dianli University Jilin 132012 China;School of Electrical & Electronic Engineering North China Electric Power University Beijing 102206 China;Global Energy Interconnection Research Institute Beijing 102211 China;Beijing Key Laboratory of DC Power Grid Technologies and Simulation Beijing 102211 China)
机构地区:[1]东北电力大学电气工程学院,吉林132012 [2]华北电力大学电气与电子工程学院,北京102206 [3]全球能源互联网研究院,北京102211 [4]直流电网技术与仿真北京市重点实验室,北京102211
出 处:《电工技术学报》2017年第6期231-239,共9页Transactions of China Electrotechnical Society
基 金:国家电网公司科技发展计划资助项目(NEDU20150002)
摘 要:针对柔性直流输电的特点,将其稳定性分析分为两部分,即柔直系统直流侧稳定性分析和交直流互联的稳定性分析。对于直流侧的稳定性分析,首先建立柔直系统的简化复频域电路,然后得到等效环路增益,采用Middlebrook判据进行稳定性判断;对于柔直系统与交流互联网络,首先探讨其稳定性机理,然后通过dq旋转坐标系下的电流环控制结构框图构建换流站的等效电路,并推导出换流站的等效导纳表达式,最后通过注入非特征谐波电流法进行交流侧阻抗检测,利用交直流阻抗比的频域特性进行稳定性判断,找出稳定的控制参数域。利用PSCAD/EMTDC软件对实际工程中不同等效场景下交流侧阻抗对稳定性的影响进行仿真,证明了采用所提方法进行稳定性判断及控制参数整定的有效性。According to the characteristics of the voltage source converter based high voltage direct current(VSC-HVDC),the paper divides the stability analysis of VSC-HVDC into two parts,namely VSC-HVDC DC side stability analysis and AC-DC interconnected stability analysis.Regarding the DC side stability analysis,the VSC-HVDC simplified circuit in complex-frequency domain isestablished,and then the equivalent loop gain is obtained,at last Middlebrook criterion judges the stability of VSC-HVDC.For the stability between VSC-HVDC and AC network,its stability principleis firstly discussed,and then the equivalent circuit of VSC is built by the structure diagram of thecurrent loop control in dq reference frame,finally the equivalent admittance expressions of converter station are deduced.Thereafter,the AC impedance is tested through the uncharacteristic harmonics current injection method,while the frequency domain characteristic of AC-DC impedance ratio is used as stability judging criterion to find the stable control parameters domain.The time domain electromagnetic transient simulation in PSCAD/EMTDC shows the impacts of different AC impedanceson VSC-HVDC system stability,which verifies the proposed stability criterion analysis and control parameter setting method.
关 键 词:柔性直流输电 稳定性 Middlebrook判据 交直流阻抗比 控制参数整定
分 类 号:TM712[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145