Disagreement in middle ear volume estimation between tympanometry and three-dimensional volume reconstruction in the context of tympanic membrane perforation  被引量:2

Disagreement in middle ear volume estimation between tympanometry and three-dimensional volume reconstruction in the context of tympanic membrane perforation

在线阅读下载全文

作  者:David J.Carpenter Debara L.Tucci David M.Kaylie Dennis O.Frank-Ito 

机构地区:[1]Division of Head and Neck Surgery&Communication Sciences,Department of Surgery,Duke University Medical Center,Durham,NC,USA [2]Computational Biology&Bioinformatics PhD Program,Duke University,Durham,NC,USA [3]Department of Mechanical Engineering and Materials Science,Duke University,Durham,NC,USA

出  处:《Journal of Otology》2017年第2期74-79,共6页中华耳科学杂志(英文版)

摘  要:Introduction: Middle ear volume(MEV) is a clinically relevant parameter across middle ear diseases. MEV values between these techniques have never before been tested for agreement in ears with perforated tympanic membranes(TMs).Methods: Middle ears were identified from 36 patients ranging 18-89 years of age with TM perforations who underwent tympanometry and temporal bone computed tomography(CT) between 2005 and 2015. MEVs calculated by both tympanometry and three-dimensional volume reconstruction(3DVR) were analyzed for agreement using Bland Altman plots. The differences between tympanometric and 3DVR MEV values for each given middle ear were characterized across MEV quartiles(1= smallest; 4= largest) and across increasing states of middle ear disease using Kruskale Wallis and Wilcoxon testing with Bonferroni correction.Results: Bland Altman plots demonstrated significant disagreement between MEV measurement techniques. Differences between tympanometric(T) and 3DVR MEV values were significantly greater with increasing average(i.e.(Tt3DVR)/2)) MEV per linear regression(p < 0.0001). Significance was demonstrated between fourth and first average MEV quartiles(p= 0.0024), fourth and second quartiles(p= 0.0024), third and first quartiles(p= 0.0048), and third and second quartiles(p= 0.048). Absolute MEV difference was not significantly different across varying states of middle ear disease(p= 0.44).Conclusion: Statistically and clinically significant disagreement was demonstrated between tympanometric and 3DVR MEV values. Studies that vary in MEV estimation techniques may be expected to demonstrate significantly different results. These preliminary results suggest that clinicians should endeavor to seek further confirmation when interpreting high tympanometric MEV values.Introduction: Middle ear volume(MEV) is a clinically relevant parameter across middle ear diseases. MEV values between these techniques have never before been tested for agreement in ears with perforated tympanic membranes(TMs).Methods: Middle ears were identified from 36 patients ranging 18-89 years of age with TM perforations who underwent tympanometry and temporal bone computed tomography(CT) between 2005 and 2015. MEVs calculated by both tympanometry and three-dimensional volume reconstruction(3DVR) were analyzed for agreement using Bland Altman plots. The differences between tympanometric and 3DVR MEV values for each given middle ear were characterized across MEV quartiles(1= smallest; 4= largest) and across increasing states of middle ear disease using Kruskale Wallis and Wilcoxon testing with Bonferroni correction.Results: Bland Altman plots demonstrated significant disagreement between MEV measurement techniques. Differences between tympanometric(T) and 3DVR MEV values were significantly greater with increasing average(i.e.(Tt3DVR)/2)) MEV per linear regression(p < 0.0001). Significance was demonstrated between fourth and first average MEV quartiles(p= 0.0024), fourth and second quartiles(p= 0.0024), third and first quartiles(p= 0.0048), and third and second quartiles(p= 0.048). Absolute MEV difference was not significantly different across varying states of middle ear disease(p= 0.44).Conclusion: Statistically and clinically significant disagreement was demonstrated between tympanometric and 3DVR MEV values. Studies that vary in MEV estimation techniques may be expected to demonstrate significantly different results. These preliminary results suggest that clinicians should endeavor to seek further confirmation when interpreting high tympanometric MEV values.

关 键 词:Middle EAR VOLUME TYMPANOMETRY THREE-DIMENSIONAL VOLUME reconstruction Tympanic membrane PERFORATION 

分 类 号:R764[医药卫生—耳鼻咽喉科]

 