检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:宋聪颖 SONG Congying(Department of Mechanical and Electrical Engineering,Anhui Water Conservancy Technical College,Hefei 231603,Anhui,China)
机构地区:[1]安徽水利水电职业技术学院机电工程系,安徽合肥231603
出 处:《电气传动》2017年第8期34-37,共4页Electric Drive
摘 要:研究了一种新型软开关三电平逆变器(D-NPC)。由于此拓扑的独特性,使其可以工作在死区与无死区模式下,且2种模式都可以实现开关管的软开关动作。详细分析了2种模式下的换相过程,通过分析2种模式输出电压的区别,可知无死区模式输出电流基波更高、THD更低,可得无死区模式为D-NPC软开关三电平逆变器较优工况。最后通过Matlab仿真验证了理论分析的正确性。the research of a novel soft switching three level inverter was presented.Based on the uniqueness of this topology,it could be worked in the dead?zone and non?dead?zone mode,the soft switching action of the switch could be realized in the two modes.The commutation process of the two modes was analysed in detail.By analyzing the difference of output voltage,the no?dead?zone model had higher output fundamental current and lower THD was concluded.So the non?dead?zone mode was the better condition of D?NPC soft switching three level inverter.Finally,the correctness of the theoretical analysis is verified by Matlab simulation.