JK2005与5320A校准性能研究——耐压测试仪  

Research on Calibration Performance of JK2005 and 5320A——Withstand Voltage Tester

在线阅读下载全文

作  者:经蕾 Jing Lei(Anhui Changjiang Institute of Metrology & Measurement,Anhui Hefei 230088)

机构地区:[1]安徽省长江计量所,安徽合肥230088

出  处:《电子质量》2017年第8期59-61,73,共4页Electronics Quality

摘  要:该文对耐压测试仪使用国产JK2005和进口的5320A分别进行校准检定。并详细地分析了不确定度的评定,通过比较国产与进口电气安全校准装置的校准情况,说明使用的一般方法与步骤,并为相关检测机构和人员根据不同需求选择不同仪器提供了参考。并证明了国产仪器可操作性技术性能比较好。不用一味追求进口仪器。In this paper,The withstand voltage tester is calibrated and calibrated respectively by JK2005and5320A.And a detailed analysis of the uncertainty of the calibration,through the comparison of domestic and imported electrical safety calibration device,explains the general methods and steps to use,and provide reference for the relevant inspection agencies and personnel according to the different needs of different instruments.It is proved that the domestic instrument is operable and better in technical performance.Do not blindly pursue the imported equipment.

关 键 词:耐压测试仪 国产 进口 不确定度评定 

分 类 号:TB971[一般工业技术—计量学]

 