摘  要:目的分析不同预处理方法对HBV污染手术器械清洗效果的影响.方法抽取HBV污染手术器械600件,随机平均分配到A、B、C、D四组预处理方法中,预处理后,再将四组器械放入全自动清洗消毒器清洗,清洗结束,用纯水冲洗器械留取样本,采用目测、5倍带光源放大镜检查清洁度,3M ATP荧光法检测有机物残留、酶联免疫吸附试验(ELISA)定量检测留取样本中乙型肝炎表面抗原(HBs Ag)的阳性率,评价HBV污染手术器械的清洗效果.结果 600件HBV污染手术器械经A、B、C、D 4种预处理后的清洗目测合格率依次为100.00%、82.67%、100.00%、90.67%;5倍带光源放大镜检测合格率依次为100.00%、78.67%、97.33%、85.33%;ATP荧光检测合格率依次为98.67%、72.67%、96.00%、80.00%;在上述3种检测结果中,A组与B组、D组比较,B组与C组比较,差异均具有统计学意义(P<0.01).ELISA检测HBs Ag的阳性率均为0.结论全效型多酶清洗液(1:270)浸泡10 min预处理器械,可明显提高HBV污染手术器械的清洗质量,降低器械损耗.Objective To analyze the influence of different pretreated methods on cleaning efficacy of surgical instruments polluted by hepatitis B virus(HBV).Methods600HBV-contaminated surgical instruments were selected and divided randomly into4groups of pretreatment methods A,B,C and D,after pretreatment,four groups of instruments were washed in the verified automatic cleaning sterilizer.After washing,instruments were washed with pure water,the samples were taken,and the cleanliness of the instruments was inspected visually and by5-time magnifier that has light source;the cleanliness was test by3M ATP fluorescence method;the positive rate of HBsAg was detected by Quantitative ELISA.Results The visual pass rate of thecleanliness of600HBV-contaminated surgical instruments after four types of pretreatment was100.00%,82.67%,100.00%and90.67%respectively;which was100.00%,78.67%,97.33%and85.33%by5-time magnifier that has light source;which was98.67%,72.67%,96.00%and80.00%by3MATP fluorescence method;With regard to the above three test results,Group A was compared with Group B、Group D and Group B was compared with Group C while the differences were statistically significant(P<0.01).The positive rate of HBsAg detected by ELISA was0.Conclusion Multiple Enzyme Detergent solution(1:270)can significantly improve the cleaning quality of HBV-contaminated surgical instruments,and reduce instruments loss.

关 键 词:HBV 手术器械 预处理 清洗消毒 清洗剂 清洗效果 

分 类 号:R187.3[医药卫生—流行病学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象