基  金:国家高技术研究发展计划2013AA065002;国家重点研发计划2016YFC0203704;国家重点研发计划2016YFC0209107;浙江省科技计划项目2013C11G6080001

摘  要:超低排放条件下烟尘的高精度测试一直是近年来研究的热点和难点,文章分析了超低排放烟尘测试的特点,对国内外相关测试标准进行分析,研究了测量误差的种类及原因,并基于此指导现场测试,对超低排放烟尘测试准确性评述,可为低浓度烟尘测试标准的修制定提供技术支撑。It is a hot spot and the difficulty problem for smoke dust of the high precision test under the condition of ultra-low emission in recent years.The paper analyzes the characteristics of the smoke dust test of ultra-low emission,and the relevant test standards at home and abroad,and studies the types and reasons of measurement error.Based on the guidance field tests,the paper reviews the accuracy of smoke dust test for ultra-low emission in order to provide the technical supports for the revision and formulation of the test standards of low concentration smoke dust.

关 键 词:烟尘 超低排放 燃煤电厂 滤筒 滤膜 误差分析 测量精度 