Three-Dimensional Conformal Dose Planning for Prostate Brachytherapy  

Three-Dimensional Conformal Dose Planning for Prostate Brachytherapy

在线阅读下载全文

作  者:Shihui Zhang Shan Jiang Zhiyong Yang Zhi Li 

机构地区:[1]Center for Advanced Mechanisms and Robotics,School of Mechanical Engineering,Tianjin University,Tianjin 300072,China [2]China Automotive Technology and Research Center,Tianjin 300300,China

出  处:《Transactions of Tianjin University》2018年第1期73-81,共9页天津大学学报(英文版)

基  金:supported by the National Natural Science Foundation of China(no.51175373);the Key Technology and Development Program of the Tianjin Municipal Science and Technology Commission(no.14ZCDZGX00490)

摘  要:For local radiotherapy, a three-dimensional(3D)conformal localized dose planning protocol has been established in this paper to develop a precise and reasonable dose plan. A precalculated 3D dose map for a single source is obtained using the Monte Carlo method, and the spatial dose maps are combined linearly to acquire the dose distribution. The dose distribution is visualized through the real-time display of the isodose line and isodose surface combined with the reconstructed 3D organ groups. By observing 3D dose coverage to the target volume and surrounding tissues, dose planning could be initiated with greater accuracy and precision to avoid dose dead zones and excessively high-dose levels, thus achieving the 3D conformal dose planning objective. Further research into the impact that blockages have on a needle trajectory can be conducted to optimize the insertion accuracy. A treatment planning system was developed to formulate and implement the 3D local treatment plan before the surgery,during the surgery, and after the surgery. Several experiments pertaining to both single-seed and multiple-seed dose distributions were conducted to verify the accuracy of the single-seed dose calculation module and 3D superposition dose calculation in the treatment planning system.For local radiotherapy, a three-dimensional(3D)conformal localized dose planning protocol has been established in this paper to develop a precise and reasonable dose plan. A precalculated 3D dose map for a single source is obtained using the Monte Carlo method, and the spatial dose maps are combined linearly to acquire the dose distribution. The dose distribution is visualized through the real-time display of the isodose line and isodose surface combined with the reconstructed 3D organ groups. By observing 3D dose coverage to the target volume and surrounding tissues, dose planning could be initiated with greater accuracy and precision to avoid dose dead zones and excessively high-dose levels, thus achieving the 3D conformal dose planning objective. Further research into the impact that blockages have on a needle trajectory can be conducted to optimize the insertion accuracy. A treatment planning system was developed to formulate and implement the 3D local treatment plan before the surgery,during the surgery, and after the surgery. Several experiments pertaining to both single-seed and multiple-seed dose distributions were conducted to verify the accuracy of the single-seed dose calculation module and 3D superposition dose calculation in the treatment planning system.

关 键 词:BRACHYTHERAPY I-125 SEED 3D CONFORMAL LOCALIZED DOSE PLANNING Treatment PLANNING system 

分 类 号:G64[文化科学—高等教育学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象