光致二溴甲烷离子化学电离质谱分析VOCs  被引量:2

Photoionization-Generated Dibromomethane Cation Chemical Ionization Source for Mass Spectrometric Analysis of Volatile Organic Compounds

在线阅读下载全文

作  者:蒋吉春 王艳[1,2] 刘巍 李金旭[1] 李庆运 吴称心[1,2] 花磊[1] 侯可勇 李海洋[1] JIANG Jichun;WANG Yan;LIU Wei;LI Jinxu;LI Qingyun;WU Chenxin;HUA Lei;HOU Keyong;LI Haiyang(Key Laboratory of Separation Science for Analytical Chemistry,Dalian Institute of Chemical Physics,Chinese Academy of Sciences,Dalian116023,China;University of Chinese Academy of Sciences,Beijing100039,China;Instrument Science and Electrical Engineering College of Jilin University,Changchun130026,China)

机构地区:[1]中国科学院分离分析化学重点实验室,中国科学院大连化学物理研究所,辽宁大连116023 [2]中国科学院大学,北京100039 [3]吉林大学仪器科学与电气工程学院,吉林长春130026

出  处:《质谱学报》2018年第1期10-19,共10页Journal of Chinese Mass Spectrometry Society

基  金:国家重大科学仪器设备开发专项(2011YQ05006904);863计划(2014AA06A507);国家自然科学基金(21375129)资助

摘  要:以真空紫外(VUV)灯作为电离源的单光子电离质谱(SPI-MS)分析方法是一种快速分析复杂样品中挥发性有机物(VOCs)的技术,但SPI-MS灵敏度受限于VUV灯较低的光通量及部分VOCs较小的电离截面。本工作自行研制了一种基于VUV Kr灯的新型光致二溴甲烷正离子化学电离源,并将该电离源与飞行时间质谱(TOF MS)联用进行VOCs分析。该电离源以体积分数1 000μL/L的二溴甲烷为试剂气体,利用VUV光电离产生稳定且充足的二溴甲烷正离子,二溴甲烷正离子与样品分子通过电荷转移发生化学电离,大大提高了样品的电离效率。与SPI源相比,该电离源不仅对电离能在10.0eV附近的VOCs信号强度提升100倍以上(如对2-丙醇、乙酸乙酯和3-氯丙烯分别提高了103、118和126倍),而且保持着与SPI一致的软电离特性。该电离源10s内对复杂样品EPA TO-14、TO-15/17校准标气中的42种化合物的最低检测限达到0.06μg/m3,并且因其具有较好的稳定性,在VOCs的实时在线监测方面有着广泛的应用。Volatile organic compounds(VOCs)have a serious impact on the ecological environment and human health for its characteristics of volatile and toxic.Single photoionization mass spectrometer(SPI-MS)based on vacuum ultraviolet(VUV)lamp is an efficient technique for rapid analysis of VOCs.However,its performance is limited due to relatively low photon flux density and ionization cross section.In this work,a novel photoionization generated dibromomethane cation chemical ionization(PDCI)source based on VUV Kr lamp was developed for time of flight mass spectrometry(TOF MS)to analyze VOCs.A sufficient and stable flux of CH2Br2+was generated by dibromomethane as reagent gas,and the VOCs were further ionized by reaction with CH2Br2+cations through charge transfering.The mass spectrometer used in the experiments was a home built radio frequency(rf)-only quadruple orthogonal acceleration reflectron TOF MS with the mass resolution of3000(fwhm)at m/z78.First of all,three bromoalkanes with the ionization energy higher than10.0eV while less than10.6eV were tested as reaction reagents,and the dibromomethane was chosen as the reaction reagent for PDCI source due to its simple reactant ions and high ionization efficiency.And then,to achieve better sensitivity and less backgrounds,the volume fraction of the reaction reagent and the electric field of PDCI source were optimized at1000μL/L and0.5V/cm,individually.After that,the linearity and stability of the PDCI source were evaluated by benzene,toluene,and p xylene.The linear concentration ranges,0.8-349μg/m3for benzene,0.9-411μg/m3for toluene,and2.4-474μg/m3for p xylene were obtained with the correlation coefficients of0.9965,0.9966,and0.9967,respectively.The relative standard deviations(RSDs)of the intensities of the reactant ions and the three compounds were1.45%,3.57%,4.15%and464%,respectively,within6h continuous measurement.The results indicated that the PDCI source owned good linearity and stability which can meet the needs for online quantitative and long term monitoring of

关 键 词:化学电离源 单光子电离 软电离 飞行时间质谱(TOFMS) 挥发性有机物(VOCs) 

分 类 号:O657.63[理学—分析化学]

 