转轮除湿与冷却除湿结合的新风除湿系统性能试验研究  被引量:8

Experimental Research on Performance of a Fresh Air Dehumidifying System Based on Combination of Rotary Wheel and Cooling Desiccation

在线阅读下载全文

作  者:冉广鹏 傅允准[1] RAN Guang-peng;FU Yun-zhun(Shanghai University of Engineering Science,Shanghai 201620,China)

机构地区:[1]上海工程技术大学,上海201620

出  处:《流体机械》2018年第1期73-77,共5页Fluid Machinery

摘  要:提出了一种转轮除湿与冷却除湿结合的新风除湿系统,并介绍了系统工作原理。以除湿量为研究重点,通过试验方法探究转轮除湿与冷却除湿的最佳结合方式及设定参数。结果表明:在除湿转轮处理区前后各加一表冷器时其除湿量最高;处理风进口温度对除湿量的影响不大;再生温度设定为99℃,冷冻水温度设定9℃,除湿效果最好。A fresh air dehumidifying system based on combination of rotary wheel and cooling desiccation was proposed and the system working principle was introduced.Focusing on dehumidification capacity,the optimal combination mode and setting parameters of rotary wheel and cooling desiccation were studied through experimental method.The results showed that the dehumidification capacity is the highest adding a cooler in the front and back of the rotary wheel;the inlet air temperature has little effect on the dehumidification and when regenerate temperature is 99℃,cooling water temperature is 9℃,the dehumidification effect is best.

关 键 词:转轮除湿 冷却除湿 新风系统 

分 类 号:TH138[机械工程—机械制造及自动化] TB65[一般工业技术—制冷工程]

 