SCR脱硝催化剂寿命管理研究  被引量:11

Study on Life Management of the SCR Denitrification Catalyst

在线阅读下载全文

作  者:傅玉[1] 陆强[1] 唐诗洁 庄柯[2] 胡笑颖[1] 董长青[1] FU Yu;LU Qiang;TANG Shijie;ZHUANG Ke;HU Xiaoying;DONG Changqing(National Engineering Laboratory for Biomass Power Generation Equipment, North China Electric Power University ,Beijing 102206,China;State Power Environmental Protection Research Institute,Nanjing 210031,China)

机构地区:[1]华北电力大学生物质发电成套设备国家工程实验室,北京102206 [2]国电环境保护研究院,江苏南京210031

出  处:《中国电力》2018年第3期163-169,共7页Electric Power

基  金:国家973计划资助项目(No.2015CB251501);中央高校基本科研业务费资助项目(No.2016YQ05;No.2015ZZD02)~~

摘  要:催化剂是燃煤电站SCR脱硝系统的核心,其在运行过程中会缓慢失活,及时更换失活催化剂或者加装新催化剂是保证SCR脱硝系统高效经济运行的关键。以氨逃逸量为评判标准,基于SCR反应器的基础模型和催化剂失活模型,建立了符合脱硝工况实际的催化剂寿命管理模型。该模型以氨氮摩尔比小于1的真实工况为建模条件,综合考虑了反应器入口氨氮摩尔比以及反应器内部各层催化剂入口氨氮摩尔比变化,经与实际催化剂失活时间进行比较,证明所建模型准确,假设催化剂运行工况恰当。在此基础上,根据催化剂更换或者加装情况,给出12种可能的催化剂管理方案,并以催化剂使用寿命为评价标准,从中获得了最优方案。The catalyst is the key element of the SCR denitrification system in the coal-fired power plant.It deactivates gradually during the running process.In-time replacement or supplement of the catalyst not only guarantees the denitrification efficiency,but also reduces the system reaction costs.In this work,with the ammonia slip amount as the evaluation indicator,the catalyst life management model in line with the actual conditions of the denitrification is established based on the basic model of the SCR reactor and the deactivation model of the catalyst.The actual conditions of the ammonia-nitrogen ratio less than1are adopted as the modeling conditions,with the changes of the ammonia-nitrogen ratios at the reactor inlet and each catalyst layer in the reactor in consideration.Through comparing with the actual catalyst deactivation time,it is concluded that the model is proved to be accurate and the catalyst operating conditions are assumed properly.On this basis,combining with the catalyst replacement or supplement situation,12feasible catalyst management schemes are proposed.The optimal scheme is obtained when the service life of the catalystis set as the evaluation indicator.

关 键 词:燃煤电厂 烟气脱硝 SCR 催化剂 氨逃逸 脱硝效率 催化剂寿命管理 

分 类 号:TM621[电气工程—电力系统及自动化] X511[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象