摘  要:燃煤电厂选择性催化还原法的氨区属危险化学品重大危险源,耐压试验是系统投运前必须进行的步骤之一。本文按液氨储罐、液氨管道和气氨管道分部详细介绍了耐压试验过程,并依据现场经验提出了建议。The ammonia area of the SCRmethod in coal-fired power plants is a major dangerous source of dangerous chemicals.The pressure test is one of the steps that must be carried out before the system is put into operation.In this paper,liquid ammonia storage tank,liquid ammonia pipeline and ammonia gas pipeline subsections detailed pressure test process,and based on field experience to make recommendations.