锌、镉、铅离子在原位铋修饰掺硼金刚石薄膜电极上的传感分析  被引量:7

Determination of Trace Zn(Ⅱ),Cd(Ⅱ) and Pb(Ⅱ) Metal Ions Using In-situ Bismuth-modified Boron Doped Diamond Electrode

在线阅读下载全文

作  者:高成耀[1,2] 佟建华[1] 边超[1] 孙楫舟[1] 李洋[1] 王晋芬 龚顺[1] 惠允 徐钰豪 王晓青 谢虎成 夏善红[1] 

机构地区:[1]中国科学院电子学研究所,传感技术国家重点实验室,北京100190 [2]中国人民武装警察部队学院,指挥系,廊坊065000 [3]国家纳米科学中心,北京100190

出  处:《分析化学》2018年第2期217-224,共8页Chinese Journal of Analytical Chemistry

基  金:本文系国家重点基础研究发展(973)计划项目(No.2015CB352100)、国家自然科学基金项目(No.61306010)和河北省自然科学基金项目(No.E2014507012)资助

摘  要:以原位铋修饰掺硼金刚石薄膜电极为传感电极,利用阳极溶出伏安法对重金属离子Zn^(2+)、Cd^(2+)、Pb^(2+)进行同时检测分析。原位铋修饰掺硼金刚石薄膜电极可有效提高Zn^(2+)、Cd^(2+)、Pb^(2+)的溶出峰值电流。考察了p H值、扫描方式、电极硼掺杂浓度、富集电位等参数对检测分析的影响。在优化的实验条件下,原位铋修饰BDD电极对Zn^(2+)、Cd^(2+)、Pb^(2+)传感分析具有良好的特性,在10~300μg/L浓度范围内具有良好的线性度和重复性,检出限分别为0.56、0.32和0.75μg/L(S/N=3)。干扰实验结果表明,3种重金属的相互干扰较小,除Cu^(2+)外,水中常见离子对测定干扰较小。实际水样中,3种离子的回收率为92.0%~114.0%。Bismuth modified boron doped diamond( BDD) film electrode was employed for simultaneous determination of trace Zn(Ⅱ),Cd(Ⅱ) and Pb(Ⅱ) by anodic stripping voltammetry. Bi(Ⅲ) was simultaneously in-situ deposited on bismuth modified boron doped diamond electrode with Zn (Ⅱ), Cd(Ⅱ) and Pb(Ⅱ) by preconcentration. In the presence of Bi (Ⅲ) ,the sensitivity for determination of Zn(Ⅱ),Cd(Ⅱ) and Pb(Ⅱ) was remarkably enhanced. Influence factors such as bismuth concentration,boron doped concentrations of BDD electrode,p H,preconcentration potential were investigated and optimized. Under the optimal conditions,the stripping peak currents increased linearly with the increasing concentration of Zn(Ⅱ),Cd(Ⅱ) and Pb(Ⅱ) in the range of 10-300 μg/L. The limit of detection was 0.56 μg/L for Zn(Ⅱ),0.32 μg/L for Cd(Ⅱ) and 0.75 μg/L for Pb(Ⅱ)( S/N = 3),respectively. The interference experiments showed that common ions had little influence on the determination except Cu(Ⅱ). In addition,the developed electrode displayed a good repeatability. The method was successfully applied to determination of Zn(Ⅱ),Cd(Ⅱ) and Pb(Ⅱ) in real water samples with the standard addition recoveries of 92.0%-114.0%.

关 键 词:掺硼金刚石薄膜电极 阳极溶出伏安法 重金属离子 同时检测 电化学传感器 

分 类 号:O657.1[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象