作 者:周树然[1] 姚阳[1] 郝丽玲[1] 徐礼胜[1,2] ZHOU Shu-ran;YAO Yang;HAO Li-ling;XU Li-sheng(School of Sino-Dutch Biomedical&Information Engineering,Northeastern University,Shenyang 110169,China;Key Laboratory of Medical Image Computing,Ministry of Education,Northeastern University,Shenyang 110169,China)
机构地区:[1]东北大学中荷生物医学与信息工程学院,辽宁沈阳110169 [2]东北大学教育部医学影像计算重点实验室,辽宁沈阳110169
出 处:《东北大学学报(自然科学版)》2018年第3期329-333,共5页Journal of Northeastern University(Natural Science)
基 金:国家自然科学基金资助项目(61773110;61374015;61202258);中央高校基本科研业务费专项资金资助项目(N161904002;N130404016)
摘 要:针对弹性管模型适用于模拟大中型动脉血管,不适用于模拟微小型动脉血管问题,对人体上肢血管系统建立一种弹性管与弹性腔融合模型,从而提高其模型的精度.首先分别在肱-桡动脉段建立弹性管模型,在桡-指动脉段建立弹性腔模型;然后在两模型的接触面处应用血管压力和血液流量的连续性原理,建立二者联系,导出融合模型;最后对比分析弹性管模型和弹性管与弹性腔融合模型的仿真性能.在PRD,H1,H2,t1和t 2评价指标下,弹性管与弹性腔融合模型(PRD:(4.0±2.0)%;t1:(2.5±1.7)%;t2:(3.1±1.9)%;H1:(1.9±2.1)%;H2:(1.3±1.3)%)的仿真波形和实测波形误差均低于弹性管模型(PRD:(16.5±8.3)%;t1:(3.4±2.4)%;t2:(4.5±3.7)%;H1:(22.1±14.9)%;H2:(19.7±15.3)%).结果表明,弹性管与弹性腔融合模型能够更精确地模拟人体上肢血管系统的生理状态.In response to the problem that the tube-load model is suitable to simulate large and medium-sized arteries,not suitable to simulate small arteries and arterioles,the model combining windkessel model with tube-load model was established to improve the simulation accuracy for the human upper limb vascular system.Firstly,the tube-load model was applied to the simulation from brachial artery to radial artery,and the windkessel model was established in the section from radial artery to finger artery,respectively.Secondly,based on the continuity principle of blood pressure and blood flow in the interface of two models,the relationship of the two models was built and a fusion model was derived by combining the two models.Finally,the simulation performances of the tube-load model and the fusion model were compared.With the evaluation indexes,such as PRD,H 1,H 2,t 1 and t 2,the error between the measured waveform and the simulated waveform of the fusion model(PRD:(4.0±2.0)%;t 1:(2.5±1.7)%;t 2:(3.1±1.9)%;H 1:(1.9±2.1)%;H 2:(1.3±1.3)%)is lower than that of the tube-load model(PRD:(16.5±8.3)%;t 1:(3.4±2.4)%;t 2:(4.5±3.7)%;H 1:(22.1±14.9)%;H 2:(19.7±15.3)%).The results show that the fusion model can accurately simulate the physiological state in the human upper limb vascular system.
关 键 词:心血管系统 脉搏波 弹性腔模型 弹性管模型 融合模型
分 类 号:TP391.4[自动化与计算机技术—计算机应用技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28