检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:梁旭东 LIANG Xudong(People’s Hospital of Yicheng District,Shandong,Zaozhuang 277300,China)
出 处:《河北医药》2018年第7期1011-1015,共5页Hebei Medical Journal
摘 要:目的探讨不同数量(0~3枚)内侧柱支撑螺钉重建内侧柱支撑对锁定钢板治疗肱骨近端骨折疗效的影响。方法行锁定钢板治疗的肱骨近端骨折患者184例,根据肱骨近端内侧柱支撑螺钉使用数量分为0枚支撑钉组(63例)、1枚支撑钉组(49例)、2枚支撑钉组(41例)和3枚支撑钉组(31例),比较4组骨折愈合情况、肱骨头高度丢失、肩关节功能、末次随访时骨折复位效果和并发症发生率。结果末次随访时,3枚支撑钉组、2枚支撑钉组、1枚支撑钉组、0枚支撑钉组肱骨头内翻角依次为(1.74±0.57)°、(1.96±0.93)°、(3.28±1.14)°、(6.14±2.95)°,肱骨头丢失高度依次为(1.06±0.84)mm、(2.92±1.41)mm、(5.09±2.25)mm、(6.18±2.47)mm,Constant评分依次为(79.56±7.83)、(76.13±8.45)、(64.86±7.33)、(57.64±6.68),4组比较差异有统计学意义(P<0.01);术后首次测量颈干角、骨折愈合时间、并发症发生率4组比较差异无统计学意义(P>0.05)。结论采用锁定钢板治疗肱骨近端骨折中,选择2或3枚支撑钉重建内侧柱支撑可获得较满意的效果。Objective To investigate the effects of different medial column support screw numbers(0~3)on the therapeutic effects of proximal humeral anatomical locking plate on proximal humeral fractures.Methods A total of 184 patients with proximal humeral fractures who were treated by proximal humeral anatomical locking plate in our hospital from January 2011 to March 2016 were enrolled in the study.According to proximal humeral medial column support screws numbers,these patients were divided into 0 screw support group(n=63),1 screw support group(n=49),2 screws support group(n=41)and 3 screws support group(n=31),then the fracture healing status,humerus head height loss,shoulder joint function,the fracture reduction effects at last follow up and incidence rate of complications were observed and compared among the four groups.Results At last follow-up,the humerus head varus angle in 3 screws,2 screws,1 screw,0 screw support groups was(1.74±0.57)°,(1.96±0.93)°,(3.28±1.14)°,(6.14±2.95)°,respectively,and the humerus head height loss was(1.06±0.84)mm,(2.92±1.41)mm,(5.09±2.25)mm,(6.18±2.47)mm,respectively,and Constant scores were(79.56±7.83),(76.13±8.45),(64.86±7.33),(57.64±6.68),respectively,there were significant differences among the four groups(P<0.01).However there were no significant differences in neck stem angle,fracture healing time,incidence rate of complication in the first detection after operation among the four groups(P>0.05).Conclusion In treatment of proximal humeral fractures by proximal humeral anatomical locking plate,to use 2 or 3 support screws to reconstruct medial column support can obtain satisfactory therapeutic effects.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.112