压水堆核电厂TEU监测槽废水pH值低原因分析及处理建议  

Reasons for low pH value of wastewater from TEU monitoring tank in PWR nuclear power plant and treatment suggestions

在线阅读下载全文

作  者:张庆亮 雷水雄 邹世伟 王佳思 ZHANG Qing-liang;LEI Shui-xiong;ZOU Shi-wei;WANG Jia-si(China Nuclear Power Operation Management Co.,Ltd.,Haiyan Zhejiang 314300,China)

机构地区:[1]中核核电运行管理有限公司,浙江海盐314300

出  处:《科技视界》2018年第6期123-124,共2页Science & Technology Vision

摘  要:压水堆核电厂TEU监测槽(TEU009/010Ba)的废水pH值经常偏低,给正常排放产生困难,其主要来水水源为工艺废水和TEU蒸馏水,本文分别对工艺水及蒸馏水pH值低原因进行了分析,并参考各电厂实际运行经验及历年工艺数据,得出TEU009/010BA废水pH值低的根本原因,结合现场实际情况,对TEU009/010BA废水的处理工艺提出合理化的建议。The pH value of waste water in TEU monitoring station(TEU009/010Ba)of PWR nuclear power plant is often low,which makes it difficult to discharge normally.The main source of water comes from process wastewater and TEU distilled water.The pH of process water and distilled water are respectively The reasons for the low value were analyzed,and the actual operation experience of the power plants and the process data of the previous years were referred to,and the basic reasons for the low pH value of the TEU009/010BA wastewater were obtained.Based on the actual situation at the site,reasonable proposals were made for the treatment process of the TEU009/010BA wastewater.

关 键 词:监测槽 PH值 蒸馏液 工艺废水 

分 类 号:TM623[电气工程—电力系统及自动化] TL751[核科学技术—辐射防护及环境保护]

 