检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘全利 张元良[1] 张洪潮[1] 李乾坤 LIU Quan-li;ZHANG Yuan-liang;ZHANG Hong-chao;LI Qian-kun(School of Mechanical Engineering,Dalian University of Technology,Dalian 116023,Liaoning Province,China;Qingdao Hisense Medical Device Co.,Ltd,Qingdao 266071,Shandong Province,China)
机构地区:[1]大连理工大学机械工程学院,辽宁大连116023 [2]青岛海信医疗设备股份有限公司,山东青岛266071
出 处:《医疗卫生装备》2018年第4期30-34,38,共6页Chinese Medical Equipment Journal
摘 要:目的:研究并设计一款频率和磁场强度均连续可调的正弦交变磁场治疗系统,以克服市场上交变磁场治疗系统输出频率单一且输出磁场强度有效值低等缺点。方法:以多绕组亥姆霍兹线圈为磁场发生器,在逆变技术的基础上,运用考虑死区的双极性等效面积法和变速积分增量式PID(proportion,integration,differentiation)控制算法实现线圈中磁场频率和强度的精确控制;并通过仿真计算和系统电流及磁场强度测试,验证产生的波形的准确性和磁场强度的精确度。结果:该磁场治疗系统性能较好,正弦波的总谐波失真度(total harmonic distortion,THD)满足国际标准的规定,且得到的磁场强度符合理论计算和磁场仿真预期。结论:该磁场治疗系统能够产生连续可调的磁场,对于保证医护人员开展相关研究具有积极作用,为磁疗系统的研究提供了重要的技术参考。Objective To develop a sinusoidal alternating magnetic field therapy system in order to overcome the disadvantages of the single output frequency and the low effective value of the output magnetic field strength of the alternating magnetic field therapy system in the market,of which the frequency and magnetic density both were continuously adjustable.Methods Multi winding Helmholtz coil was used as the magnetic field generator.On the basis of inverter technology,bipolar equivalent area method considering dead zone and variable speed integral incremental PID control algorithm were used to achieve the accuracy control of magnetic frequency and density in the coil.The accuracy of the resulting waveform and the accuracy of the magnetic field strength was verified by simulation calculation and system current and magnetic field strength test.Results The magnetic field treatment system gained high performance,total harmonic distortion(THD)of sine wave met the requirements of international standards.The obtained magnetic density was as expected of the simulation and calculation.Conclusion The device provides continuously adjustable magnetic field,which has a positive effect on the research for the medical staff,and technical references are provided to the research of magnetic field therapy system.
关 键 词:逆变技术 正弦交变磁场 等效面积法 变速积分增量式PID 磁场强度
分 类 号:R318.6[医药卫生—生物医学工程] TH772.1[医药卫生—基础医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7