基于双源CT灌注成像对正常颅脑血流动力学的定量研究  被引量:8

Quantitative Study of Normal Craniocerebral Hemodynamics Based on Dual Source CT Perfusion Imaging

在线阅读下载全文

作  者:杨宏志 杨如武[1] 李延静 刘国军[2] YANG Hong-zhi;YANG Ru-wu;LI Yan-jing(Department of Medical Imaging,Xidian Group Hospital,Xi'an 710077,Shanxi Province,China)

机构地区:[1]西电集团医院,陕西西安710077 [2]延安大学附属医院,陕西延安716000

出  处:《中国CT和MRI杂志》2018年第3期4-7,共4页Chinese Journal of CT and MRI

基  金:延安市科技项目(2013-KW01)

摘  要:目的探讨双源CT灌注成像在正常人群中脑血流动力学定量研究中的价值,并测量其灌注参数的正常范围。方法收集无颅脑疾病的健康志愿者30例,行颅脑CT灌注扫描,利用灌注软件测得灰质(额颞顶叶)及白质(侧脑室前后角旁)、豆状核、尾状核、内囊及丘脑的CBV、CBF、MTT和TTP,并进行统计分析。结果 1、正常成人脑灰质CBF及CBV最高,MTT及TTP最长,白质CBF及CBV最低,豆状核及尾状核MTT及TTP最短;2、额叶、颞叶及顶叶CBV、CBF、TTP比较均无统计学差异(P>0.05),仅MTT有统计学差异(P<0.05);侧脑室前、后角旁CBV、CBF、MTT比较均无统计学差异(P>0.05),侧脑室前、后角旁TTP比较有统计学差异(P<0.05);3、左右侧脑室后角旁CBF比较有统计学差异(P<0.05),余左右半球各参数均无明显统计学差异(P>0.05)。结论双源CT灌注成像可以反映正常人群脑血流动力学变化,且测得了正常成人颅脑灌注参数正常值范围,为将来进一步开展CT灌注检查及相关研究提供理论基础。Objective To investigate the value of dual source CT perfusion imaging in the quantitative study of cerebral hemodynamics in normal population and to measure the normal range of perfusion parameters.Methods A total of 30 healthy volunteers with no craniocerebral disease were collected and the CT perfusion scan was performed.The CBV、CBF、MTT and TTP of gray matter(frontal/temporal/parietal)and white matter(lateral front/back corner),cerebral blood volume,lentiform nucleus,caudate nucleus,thalamus and internal capsule was measured by perfusion software,and the statistical analysis was carried out.Results 1 The CBF and CBV of cerebral gray matter in normal adults were the highest,and MTT and TTP were the longest,the CBF and CBV of the white matter were the lowest,the MTT and TTP of the lentiform nucleus and caudate nucleus were the shortest.2 There was no significant difference in CBV,CBF,TTP between the frontal,temporal and parietal lobes(P>0.05),while there was statistically significant difference in MTT(P<0.05).There was no significant difference in CBV,CBF,MTT between the anterior and posterior lateral ventricles of the lateral ventricle(P>0.05),while there was statistically significant in TTP(P<0.05).3 There was a statistically significant difference between the left and right lateral ventricle CBF(P<0.05),and there was no significant difference in the other parameters of the left and right hemispheres(P<0.05).Conclusion Dual source CT perfusion imaging can reflect the cerebral hemodynamic changes in the normal population,and measured normal adult brain perfusion parameters of the normal reference range,to provide a theoretical basis for the further research of CT perfusion imaging and related research.

关 键 词:CT灌注成像 颅脑 血流动力学 

分 类 号:R651.1[医药卫生—外科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象