作  者:齐楸 张文彬 王同喜[1] 李树超[1] 陈辰[1] QI Qiu;ZHANG Wen-bin;WANG Tong-xi;LI Shu-chao;CHEN Chen(Tianjin Fire Research Institute of MPS,Tianjin 300381,China)

机构地区:[1]公安部天津消防研究所,天津300381

出  处:《消防科学与技术》2018年第3期372-375,共4页Fire Science and Technology

摘  要:模拟不同加热方向和加热部位的现场检测条件,利用自行设计的标准温升曲线温控加热炉,分别对多种超薄型钢结构防火涂料试件进行温控加热试验。确定在不同检测环境下温控加热炉现场检测超薄型钢结构防火涂料的可行性。The field test conditions of different heating direction and heating part were simulated,a variety of ultra-thin fire-resis-tant coating specimens for steel structure was tested by tempera-ture control heating furnace.Finally,the feasibility of detecting ul-tra-thin fire-resistant coating for steel structure on site by tempera-ture control heating furnace under different testing conditions was determined.

关 键 词:超薄型钢结构防火涂料 标准温升曲线 现场检测 加热炉 

分 类 号:X924.4[环境科学与工程—安全科学] TQ637.6[化学工程—精细化工]

 