超声与钼靶BI-RADS分类对不同直径乳腺肿块的诊断价值的对比研究  被引量:1

Comparative study on the diagnostic value of ultrasonography and molybdenum target bi-rads classification for breast masses with different diameters

在线阅读下载全文

作  者:孙燕翔[1] 杨华[1] 刘坤[1] 杨乐[1] 刘兆龙[1] SUN Yan-xiang;YANG Hua;LIU Kun;YANG Le;LIU Zhao-long(Surgery of shuguang hospital affiliated to Shanghai university of traditional Chinese medicine,Shanghai,201203,China)

机构地区:[1]上海中医药大学附属曙光医院外科,上海201203

出  处:《实用妇科内分泌电子杂志》2017年第36期5-6,共2页Electronic Journal of Practical Gynecological Endocrinology

摘  要:目的了解超声BI-RADS对不同直径乳腺肿块的诊断的准确性和钼靶BI-RADS对不同直径乳腺肿块的诊断的准确性以及两者的对比。方法选择某权威医疗机构作为了解单位,对在该医疗机构进行乳腺肿块手术的患者随机选取40名作为研究对象,具体是将这些患者随机分为两组,对照组和观察组,每组各20人。其中对照组采用超声BI-RADS诊断,而对于观察组中的患者则进行钼靶BI-RADS诊断。结果在对直径≤1cm的乳腺肿块的诊断结果上,超声BI-RADS的诊断准确性低于钼靶BI-RADS的诊断准确性;在对直径为1~2cm的乳腺肿块的诊断结果上,超声BI-RADS的诊断准确性和钼靶BI-RADS的诊断准确性基本一致;在对直径>2cm的乳腺肿块的诊断结果上,超声BI-RADS的诊断准确性高于钼靶BI-RADS的诊断准确性。结论对于不同直径大小的乳腺肿块,超声BI-RADS的诊断准确性和钼靶BI-RADS的诊断准确性不同。Objective To investigate the accuracy of ultrasound BI-RADS in the diagnosis of breast masses with different diameters and mammography BI-RADS for different diameters of breast.The accuracy of diagnosis of adenoid masses and their comparison were compared.Methods An authoritative medical institution was selected as an understanding unit to carry out milk in the medical institution.40 patients were randomly divided into two groups,the control group and the observation group.20 people.The control group was diagnosed by ultrasound BI-RADS,while the patients in the observation group were diagnosed by molybdenum target BI-RADS.Results The result is in the pair diameterThe diagnostic accuracy of ultrasound BI-RADS is lower than that of molybdenum target BIRADS in diagnosis of breast masses less than or equal to one centimeter.The diagnostic accuracy of ultrasound BIRADS is basically the same as that of molybdenum target BI-RADS in the diagnosis of breast masses with a diameter of 1~2cm.In the diagnosis of breast masses larger than two cm,the diagnostic accuracy of ultrasound BI-RADS is higher than that of molybdenum target BI-RADS.Sex.Conclusion The accuracy of ultrasound BI-RADS and the accuracy of molybdenum target BI-RADS are different for breast lumps with different diameters.

关 键 词:超声BI-RADS 钼靶BI-RADS 不同直径乳腺肿块 诊断价值 

分 类 号:R445.1[医药卫生—影像医学与核医学] R655.8[医药卫生—诊断学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象