检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:朱小龙 ZHU Xiao-long(National Measurement and Testing Center for Magnetic Materials Industry,Ningbo Institute of Measurement and Testing,Ningbo 315048,China)
机构地区:[1]宁波市计量测试研究院国家磁性材料产业计量测试中心,浙江宁波315048
出 处:《磁性材料及器件》2018年第5期48-51,59,共5页Journal of Magnetic Materials and Devices
摘 要:采用电感耦合等离子体发射光谱法(ICP-OES)测定镨钕合金配分量,并对测试结果进行不确定度评定。分析了影响配分量测定结果的各个不确定度分量和灵敏系数,并对其进行计算与合成。最终得到Pr的配分量为29.2%,Nd的配分量为70.6%,扩展不确定度为U=0.9%,k=2,其他元素的扩展不确定度为U=0.01%,k=2。计算结果表明浓度测量重复性和标准曲线拟合时引入的相对不确定度分量较大,含量较高的Pr和Nd元素的测定引入的不确定度为主要影响因素。The relative content of praseodymium-neodymium alloy was measured with ICP-OES,and its determination uncertainty evaluated.The various factors and sensitivity coefficient affecting the uncertainty of the result were analyzed,and its synthesis were calculated.The relative content of praseodymium and neodymium was 29.2%,and 70.6%,respectively,and the expansion uncertainty was(U=0.9%,k=2).The expansion uncertainty of the other elements was(U=0.01%,k=2).The results show that the measurement reproducibility and calibration curve fitting are the larger factors affecting the relative uncertainty.The uncertainty of the determination of praseodymium and neodymium were the main influencing factors.
关 键 词:电感耦合等离子体光谱法 镨钕合金 配分量 不确定度
分 类 号:TG115.33[金属学及工艺—物理冶金] TG13[金属学及工艺—金属学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.189.186.244