摘 要:间歇空调开机阶段建筑室内的温度变化会影响室内的热舒适性。空调开机阶段房间室内温度变化不仅与房间围护结构特性等多种因素有关,而且与使用的空调末端送风方式、室外环境有关。通过实验的方法对比研究了板房冬夏两季室内的温变特性,以及冬季板房在不同的空调送风方式和外扰作用下,空调开机阶段室内的温度变化规律。The temperature change of the building room during the starting stage of the intermittent air conditioning will affect the indoor thermal comfort.The room temperature changes in the adjustment of the starting stage is not only related to the characteristics of the room retaining structure,but also related to the air conditioning terminal air supply mode and the outdoor environment.By the method of experimental comparatively studied the temperature change characteristic of the board room in winter and summer,as well as the board room in different ways of air supply and the role of external disturbance,the temperature variation of indoor air conditioning boot stage in winter.