作 者:陈家华[1,2] 邹鹰 卢启鹏[3] 王勇[1] 薛松[1] CHEN Jia-hua;ZOU Ying;LU Qi-peng;WANG Yong;XUE Song(Shanghai Institute of Applied Physics,Chinese Academy of Sciences,Shanghai 201800,China;State Key Laboratory of Applied Optics,Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China;University of Chinese Academy of Sciences,Beijing 100049,China)
机构地区:[1]中国科学院上海应用物理研究所,上海201800 [2]中国科学院大学,北京100049 [3]中国科学院长春光学精密机械与物理研究所应用光学国家重点实验室,吉林长春130033
出 处:《光学精密工程》2018年第9期2312-2318,共7页Optics and Precision Engineering
基 金:国家自然科学基金资助项目(No.11475251)。
摘 要:为了确保光栅单色器温度起伏引起的能量漂移不影响光束线的表观能量分辨率,建立了单色器高精度的恒温环境。结合上海光源梦之线设计,根据光栅衍射方程推导出单色器温差与能量漂移之间的关系;据此设计了沿光束方向温度起伏较小的单色器恒温环境,测试了温度控制系统不同条件下的长期温度稳定性,并通过长时间多次测量氮气K边吸收谱的方法,得到了相应的能量漂移。结果显示:温度控制系统未启动的情况下,棚屋内最大温度变化约为0.62K,测得的能量漂移约为49 meV;温度控制系统使用独立冷水机时,最大温度变化约为0.20 K,相应的能量漂移约为17meV。实验表明,建立的单色器恒温环境满足设计要求,使得单色器温差引起的能量漂移对梦之线表观能量分辨率的影响得到有效控制。In order to ensure that energy drift from temperature fluctuation of the grating monochromator does not affect apparent energy resolution of the beamline,a high-accuracy constant temperature environment(CTE)was built for the monochromator.Combined with the design of Dreamline beamline at Shanghai Synchrotron Radiation Facility,the relationship between the temperature difference at the monochromator and the energy drift was established by the grating equation.Based on that,the CTE of the monochromator was designed with tiny temperature fluctuations along the beam direction,and long-time temperature stability was tested under different conditions of temperature-controlled system(TCS);then,the corresponding energy drift was obtained through measuring K-edge absorption spectra of nitrogen several times over a long time.The results show that the maximum temperature fluctuation was 0.62 K and the corresponding energy drift was about 49 meV when the TCS was off;in contrast,when it was working with a stand-alone chiller,the maximum temperature fluctuation became 0.20 K and the corresponding energy drift reduced to around 17 meV.The results demonstrated that the built CTE of the monochromator meets the design requirement,and the energy drift from the temperature difference of the monochromator has little effect on the apparent energy resolution of the Dreamline beamline.
关 键 词:光栅单色器 温度起伏 能量漂移 气体吸收谱 能量分辨率
分 类 号:TL99[核科学技术—核技术及应用] TH122[机械工程—机械设计及理论]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.249