Diagnostic performance of high resolution computed tomography in otosclerosis  被引量:2

Diagnostic performance of high resolution computed tomography in otosclerosis

在线阅读下载全文

作  者:Todd Kanzara Jagdeep Singh Virk 

机构地区:[1]ENT Department,Countess of Chester Hospital [2]ENT Department,Royal National Throat,Nose and Ear Hospital

出  处:《World Journal of Clinical Cases》2017年第7期286-291,共6页世界临床病例杂志

摘  要:AIM To determine the sensitivity and specificity of high resolution computed tomography(HRCT) in the diagnosis of otosclerosis.METHODS A systematic literature review was undertaken to include Level I-III studies(Oxford Centre for Evidenced based Medicine) that utilised HRCT to detect histology confirmed otosclerosis.Quantitative synthesis was then performed.RESULTS Based on available level III literature,HRCT has a relatively low sensitivity of 58%(95%CI: 49.4-66.9),a high specificity,95%(95%CI: 89.9-98.0) and a positive predictive value of 92%(95%CI: 84.1-95.8).HRCT is better at diagnosing the more prevalent fenestral form of otosclerosis but remains vulnerable to inframillimetre,retrofenestral and dense sclerotic lesions,despite the advent of more advanced CT scanners with improved collimation.CONCLUSION Whilst the diagnosis of otosclerosis remains largely clinical,HRCT remains the gold standard imaging of choice for the middle ear and serves as a useful adjunct to the clinician,helping to delineate extent of disease and exclude other causes.AIM To determine the sensitivity and specificity of high resolution computed tomography(HRCT) in the diagnosis of otosclerosis.METHODS A systematic literature review was undertaken to include Level I-III studies(Oxford Centre for Evidenced based Medicine) that utilised HRCT to detect histology confirmed otosclerosis.Quantitative synthesis was then performed.RESULTS Based on available level III literature,HRCT has a relatively low sensitivity of 58%(95%CI: 49.4-66.9),a high specificity,95%(95%CI: 89.9-98.0) and a positive predictive value of 92%(95%CI: 84.1-95.8).HRCT is better at diagnosing the more prevalent fenestral form of otosclerosis but remains vulnerable to inframillimetre,retrofenestral and dense sclerotic lesions,despite the advent of more advanced CT scanners with improved collimation.CONCLUSION Whilst the diagnosis of otosclerosis remains largely clinical,HRCT remains the gold standard imaging of choice for the middle ear and serves as a useful adjunct to the clinician,helping to delineate extent of disease and exclude other causes.

关 键 词:OTOSCLEROSIS HIGH RESOLUTION COMPUTED TOMOGRAPHY Otospongiosis Retrofenestral Sensitivity SPECIFICITY Fenestral COMPUTED TOMOGRAPHY 

分 类 号:R764[医药卫生—耳鼻咽喉科] R816.96[医药卫生—临床医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象