Posterior interosseous nerve localization within the proximal forearm-a patient normalized parameter  被引量:2

Posterior interosseous nerve localization within the proximal forearm-a patient normalized parameter

在线阅读下载全文

作  者:Srinath Kamineni Crystal R Norgren Evan M Davidson Ellora P Kamineni Andrew S Deane 

机构地区:[1]Elbow Shoulder Research Centre,Depart-ment of Orthopaedics and Sports Medicine,University of Kentucky [2]University of Kentucky College of Medicine [3]Paul Laurence Dunbar High School [4]Department of Anatomy and Cell Biology,Indiana University School of Medicine

出  处:《World Journal of Orthopedics》2017年第4期310-316,共7页世界骨科杂志(英文版)

摘  要:AIM To provide a "patient-normalized" parameter in the proximal forearm. METHODS Sixty-three cadaveric upper extremities from thirty-five cadavers were studied. A muscle splitting approach was utilized to locate the posterior interosseous nerve(PIN) at the point where it emerges from beneath the supinator. The supinator was carefully incised to expose the midpoint length of the nerve as it passes into the forearm while preserving the associated fascial connections, thereby preserving the relationship of the nerve with the muscle. We measured the transepicondylar distance(TED), PIN distance in the forearm's neutral rotation position, pronation position, supination position, and the nerve width. Two individuals performed measurements using a digital caliper with inter-observer and intraobserver blinding. The results were analyzed with the Wilcoxon-Mann-Whitney test for paired samples. RESULTS In pronation, the PIN was within two confidence intervals of 1.0 TED in 95% of cases(range 0.7-1.3 TED); in neutral, within two confidence intervals of 0.84 TED in 95% of cases(range 0.5-1.1 TED); in supination,within two confidence intervals of 0.72 TED in 95% of cases(range 0.5-0.9 TED). The mean PIN distance from the lateral epicondyle was 100% of TED in a pronated forearm, 84% in neutral, and 72% in supination. Predictive accuracy was highest in supination; in all cases the majority of specimens(90.47%-95.23%) are within 2 cm of the forearm position-specific percentage of TED. When comparing right to left sides for TEDs with the signed Wilcoxon-Mann-Whitney test for paired samples as well as a significance test(with normal distribution), the P-value was 0.0357(significance-0.05) indicating a significant difference between the two sides.CONCLUSION This "patient normalized" parameter localizes the PIN crossing a line drawn between the lateral epicondyle and the radial styloid. Accurate PIN localization will aid in diagnosis, injections, and surgical approaches.AIM To provide a "patient-normalized" parameter in the proximal forearm. METHODS Sixty-three cadaveric upper extremities from thirty-five cadavers were studied. A muscle splitting approach was utilized to locate the posterior interosseous nerve(PIN) at the point where it emerges from beneath the supinator. The supinator was carefully incised to expose the midpoint length of the nerve as it passes into the forearm while preserving the associated fascial connections, thereby preserving the relationship of the nerve with the muscle. We measured the transepicondylar distance(TED), PIN distance in the forearm's neutral rotation position, pronation position, supination position, and the nerve width. Two individuals performed measurements using a digital caliper with inter-observer and intraobserver blinding. The results were analyzed with the Wilcoxon-Mann-Whitney test for paired samples. RESULTS In pronation, the PIN was within two confidence intervals of 1.0 TED in 95% of cases(range 0.7-1.3 TED); in neutral, within two confidence intervals of 0.84 TED in 95% of cases(range 0.5-1.1 TED); in supination,within two confidence intervals of 0.72 TED in 95% of cases(range 0.5-0.9 TED). The mean PIN distance from the lateral epicondyle was 100% of TED in a pronated forearm, 84% in neutral, and 72% in supination. Predictive accuracy was highest in supination; in all cases the majority of specimens(90.47%-95.23%) are within 2 cm of the forearm position-specific percentage of TED. When comparing right to left sides for TEDs with the signed Wilcoxon-Mann-Whitney test for paired samples as well as a significance test(with normal distribution), the P-value was 0.0357(significance-0.05) indicating a significant difference between the two sides.CONCLUSION This "patient normalized" parameter localizes the PIN crossing a line drawn between the lateral epicondyle and the radial styloid. Accurate PIN localization will aid in diagnosis, injections, and surgical approaches.

关 键 词:Posterior interosseous NERVE RADIAL NERVE Transepicondylar distance RADIAL tunnel SYNDROME SUPINATOR SYNDROME 

分 类 号:R322[医药卫生—人体解剖和组织胚胎学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象