作 者:罗婷 李孟飞 赵云松[1,2] LUO Ting;LI Meng-fei;ZHAO Yun-song(School of Mathematical Sciences,Capital Normal University,Beijing 100048,China;Detecting and Imaging Engineering Research Center of Beijing Higher Institutions,Beijing 100048,China;School of Electromechanical Engineering,Guangdong University of Technology,Guangzhou,Guangdong 510006,China)
机构地区:[1]首都师范大学数学科学学院,北京100048 [2]检测成像北京高校工程研究中心,北京100048 [3]广东工业大学机电工程学院,广东广州510006
出 处:《电子学报》2018年第11期2580-2587,共8页Acta Electronica Sinica
基 金:国家自然科学基金(No.61771324;No.61401289;No.61371195)
摘 要:在X射线计算机断层(CT)成像领域,多种应用需要准确的X射线能谱信息,包括能谱CT图像重建、CT图像硬化校正、CT图像的定量分析等.然而,由于CT系统中X光机发出的射线流强很大,X射线能谱一般难以直接测量,更为常用的方法是利用不同厚度模体的投影数据,间接估计能谱.该类方法将能谱估计问题转化为一组病态线性方程组的求解问题.为了获得较为准确的X射线能谱,通常需要测量多组投影数据,工作量大.针对该问题,本文提出一种新的X射线能谱估计方法.该方法利用二次有理分式拟合多能投影曲线,然后利用多能投影曲线上的采样点间接估计X射线能谱.由于二次有理分式参数少,因此该方法仅需少量的测量点即可拟合出高精度的多能投影曲线.实验表明:本文方法仅需要3个测量点就可以达到传统方法使用十几个测量点估计的X射线能谱的精度,显著减少了采样数量,进而减少能谱估计的工作量.仿真和实采数据都验证了方法的有效性.Knowledge of X-ray spectrum is essential in many applications of X-ray computed tomography(CT),such as spectral CT imaging,beam hardening correction,quantitative analysis of CT images,etc.But the spectrum of an X-ray source is hard to measure with X-ray spectrometer directly due to strong X-ray flux emitted.Other kind of attractive methods are indirect,which estimate the x-ray spectrum from a set of projection data of phantoms with different thicknesses.In indirect methods,the spectrum estimation problem is boiled down to a set of ill conditioned linear equations.To acquire accurate spectrum,a large number of measurements are required,which needs heavy workload.To overcome the abovementioned obstacle,we propose a novel X-ray spectrum estimation method that first fits the polychromatic projection curve with quadratic rational fraction,and then estimate the X-ray spectrum from the sampling points of the fitted curve.As a quadratic rational fraction includes only three parameters,only a few measurements are needed to get an accurate fitting.Numerical experiments show that the accuracy of the X-ray spectrum estimated through the proposed method with three measurements is commensurate to that estimated with tradition method from over a dozen of measurements.Therefore,the proposed method lessens the workloads effectively.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.63