重庆北碚6·5雷击事故分析及其防护措施研究  被引量:3

Cause Analysis and Protection Measures of 6.5 Lightning Accident in Beibei,Chongqing

在线阅读下载全文

作  者:李光兵 徐前进 李强 何遂 张爽 LI Guang-bing;XU Qian-jin;LI Qiang;HE Sui;ZHANG Shuang(Beibei Meteorological Bureau,Chongqing 400700,China)

机构地区:[1]重庆市北碚区气象局,重庆400700

出  处:《西南师范大学学报(自然科学版)》2018年第11期141-145,共5页Journal of Southwest China Normal University(Natural Science Edition)

基  金:北碚区科技计划项目(2018-29)

摘  要:针对重庆北碚2013年6月5日20时50分左右发生的一次雷击事件,通过雷击事故现场勘查,并结合闪电定位、探空、卫星云图等监测资料,认定该起雷电灾害事故是由于防雷装置安装不规范、线缆布设不合理所致.提出了相应的雷电防护措施,可为雷电灾害调查鉴定提供参考.In this paper,lightning strikes has been analyzed that occurred in Beibei,Chongqing at about 20:50 on June 5,2013.By lightning the scene of the accident investigation,and combined with lightning orientation,radiosonde data,satellite cloud pictures,such as monitoring data,identified the lightning accident is due to lightning protection device installation specification,cable layout is not reasonable.The corresponding lightning protection measures are put forward,which can provide reference for the investigation and appraisal of lightning disaster.

关 键 词:雷击 原因 分析 防护措施 

分 类 号:P429[天文地球—大气科学及气象学]

 