二氧化钛纳米管阵列/钛pH电极制备与表征  被引量:4

Preparation and Characterization of Titanium Dioxide Nanotube Array/Titanium pH Electrode

在线阅读下载全文

作  者:李振[1,2] 刘寒蒙 姚志霞 孙玉静 李壮[1,2,3] LI Zhen;LIU Han-Meng;YAO Zhi-Xia;SUN Yu-Jing;LI Zhuang(State Key Laboratory of Electroanalytical Chemistry,Changchun Institute of Applied Chemistry, Chinese Academy of Sciences,Changchun 130022,China;University of Chinese Academy of Sciences,Beijing 100049,China;University of Science and Technology of China,Hefei 230026,China)

机构地区:[1]中国科学院长春应用化学研究所电分析化学国家重点实验室,长春130022 [2]中国科学院大学,北京100049 [3]中国科学技术大学,合肥230026

出  处:《分析化学》2018年第12期1961-1967,共7页Chinese Journal of Analytical Chemistry

基  金:国家重点研究发展计划(No.2016YFC1400601-2);国家自然科学基金项目(No.21405146)资助~~

摘  要:采用阳极氧化法,在含有NH_4F以及乙二醇和水的混合溶液中,阳极氧化金属钛丝,制备二氧化钛纳米管阵列/钛(TiO_2NTAs/Ti)作为pH电极。利用扫描电镜(SEM)、X射线衍射(XRD)和X射线光电子能谱(XPS)对电极进行了表征。考察了电极的亲水性以及表面化学吸附氧(—OH)(性能,探究了pH响应机理。当控制电解电压为30V、电解液为含有NH_4F(0.5%,w/w)以及乙二醇和水(9∶1,V/V)的混合溶液、阳极氧化时间为10 min时,制备的TiO_2NTAs/Ti电极在B-R缓冲溶液(pH=3~11)中具有最佳pH响应,灵敏度为(-55.17±0.28) mV/pH,相关系数(R^2)>0.9966。常见离子对电极的影响可以忽略不计。制备的pH电极具有良好的稳定性,并成功用于维生素饮料和海水pH值的测定。A method for rapidly preparing titanium dioxide nanotube array/titanium(TiO 2NTAs/Ti)as a pH electrode by using anodization method in a mixed solution containing NH 4F and ethylene glycol and water was established.The electrodes were characterized by scanning electron microscopy(SEM),X-ray diffraction(XRD)and X-ray photoelectron spectroscopy(XPS).The possible pH response mechanisms were discussed by the hydrophilicity,specific surface area,and surface chemisorbed oxygen(OH)of the electrodes.Under the optimized conditions including electrolysis voltage of 30 V,a mixed solution containing NH 4F(0.5%,w/w)and ethylene glycol and water(9∶1,V/V)as electrolyte and anodization time of 10 min,the prepared TiO 2NTAs/Ti electrode in Beretan-Robson(B-R)buffer solution(pH=3-11)exhibited an excellent pH response with a sensitivity of(-55.17±0.28)mV/pH and a correlation coefficient(R 2)of above 0.9966.The results of the ion interference experiments showed that the effect of common ion on the electrode was negligible.The electrode had good stability and was successfully applied to the determination of pH value of vitamin drink and seawater.

关 键 词:二氧化钛 纳米管 PH电极 阳极氧化 金属氧化物 

分 类 号:O657.1[理学—分析化学] TB383.1[理学—化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象