Reverse polarity shoulder replacement: Current concepts and review of literature  被引量:9

Reverse polarity shoulder replacement: Current concepts and review of literature

在线阅读下载全文

作  者:Ling Hong Lee Aravind Desai 

机构地区:[1]Specialist Registrar,Trauma and Orthopaedics,Northern Deanery,Newcastle Upon Tyne,NE12 8RF,United Kingdom

出  处:《World Journal of Orthopedics》2014年第3期255-261,共7页世界骨科杂志(英文版)

摘  要:Shoulder replacement in cuff tear arthropathy(CTA)is an unsolved challenge.CTA poses a soft tissue deficiency in an arthritic glenohumeral joint which the anatomical total shoulder replacement and hemiarthroplasty cannot reliably provide stability,range of movement,function or satisfactory long term outcome.In the past two decades since the introduction of the reverse shoulder replacement,the prosthesis has evolved and has shown promising results.It is a partially constraint joint by virtue of its design features.The reversal of the concavity and convexity of the joint to the proximal humerus and the glenoid,respectively,also shifts and improves its center of rotation onto the osseous surface of the glenoid with less exposure to shear stress.It is a successful pain relieving procedure,offering good outcome in patients with irreparable massive rotator cuff tear with or without osteoarthritis.Consequently,this has led to wider use and expansion of its indication to include more complex elective and trauma cases.Whereas originally used in the more elderly patients,there is increasingly more demand in the younger patients.It is important to have good quality long term data to support these increasing indications.Therefore,we review the literature on the concepts of reverseshoulder replacement and the contemporary evidence.Shoulder replacement in cuff tear arthropathy(CTA) is an unsolved challenge. CTA poses a soft tissue deficiency in an arthritic glenohumeral joint which the anatomical total shoulder replacement and hemiarthroplasty cannot reliably provide stability, range of movement, function or satisfactory long term outcome. In the past two decades since the introduction of the reverse shoulder replacement, the prosthesis has evolved and has shown promising results. It is a partially constraint joint by virtue of its design features. The reversal of the concavity and convexity of the joint to the proximal humerus and the glenoid, respectively, also shifts and improves its center of rotation onto the osseous surface of the glenoid with less exposure to shear stress. It is a successful pain relieving procedure, offering good outcome in patients with irreparable massive rotator cuff tear with or without osteoarthritis. Consequently, this has led to wider use and expansion of its indication to include more complex elective and trauma cases. Whereas originally used in the more elderly patients, there is increasingly more demand in the younger patients. It is important to have good quality long term data to support these increasing indications. Therefore, we review the literature on the concepts of reverseshoulder replacement and the contemporary evidence.

关 键 词:REVERSE SHOULDER replacement Biomechanic CUFF TEAR ARTHROPATHY SHOULDER arthritis Proximal HUMERUS fracture Review 

分 类 号:R687.3[医药卫生—骨科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象