作  者:陈静杰 顾泽龙 陆道溢 CHEN Jingjie;GU Zelong;LU Daoyi(College of Electronic Information and Automation,CAUC,Tianjin 300300,China;Research Centre for Environment and Sustainable Development of CAAC,Tianjin 300300,China;National Engineering Laboratory for Integrated Traffic Data Application Technology Tianjin 300300,China)

机构地区:[1]中国民航大学电子信息与自动化学院,天津300300 [2]中国民航环境与可持续发展研究中心(智库),天津300300 [3]综合交通大数据应用技术国家工程实验室,天津300300

出  处:《电子器件》2018年第6期1532-1537,共6页Chinese Journal of Electron Devices

基  金:国家科技支撑计划项目(2012BAC20B03);民航局节能减排专项项目(DPDSR0010)

摘  要:为监测航站楼内环境质量,设计了基于WIA-PA环境参数无线实时监测系统。该系统由多个检测节点组网,对航站楼室内各区域CO2浓度及温度进行采集。系统采用STM8作为检测器节点微控制器,通过变周期数据传输机制及WIA-PA协议将采集的航站楼各区域环境参数数据传输到上位机。上位机监测软件通过开辟多线程实现数据可视化显示。实验和应用结果表明,采用变周期数据传输模式,节点功耗可降低66.97%,网络平均丢包率为0.43%。系统功耗低,数据传输稳定。In order to monitor the environment quality of the terminal,a wireless real-time environment parameters monitoring system based on WIA-PA is designed.The system is set up by multiple detection nodes,and the CO2 concentration and temperature of the indoor area of the terminal are collected.It uses STM8 as the detector node micro controller,and transects the environmental parameters data of the collected terminals to the host computer through the variable period data transmission mechanism and WIA-PA protocol.The monitoring software of the upper computer realizes the visualization of data by multiple threads.The experimental and application results indicate the power consumption of nodes by variable cycle acquisition can be reduced by 66.97%,and the average packet loss rate of network is 0.43%,revealing the fact that low power consumption and the stable data transmission.

关 键 词:环境监测 WIA-PA 变周期采集 多线程 数据显示 

分 类 号:TP273[自动化与计算机技术—检测技术与自动化装置]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象