有/无泵辅助板式蒸发器环路热管系统性能的实验研究  被引量:1

Experimental Study on Plate Evaporator Loop-Heat-Pipe Systems with/without Pump-Assistance

在线阅读下载全文

作  者:张伟龙 魏新利[1,2] 关中杰 孟祥睿[1,2] 刘华东[1,2] 马新灵[1,2] ZHANG Wei-long;WEI Xin-li;GUAN Zhong-jie;MENG Xiang-rui;LIU Hua-dong;MA Xin-ling(School of Chemical Engineering and Energy, Zhengzhou University, Zhengzhou 450001, China;Research Center on the Technology and Equipments for Energy Saving in Thermal Energy System,Ministry of Education, Zhengzhou 450001, China)

机构地区:[1]郑州大学化工与能源学院,河南郑州450001 [2]热能系统节能技术与装备教育部工程研究中心,河南郑州450001

出  处:《高校化学工程学报》2018年第6期1299-1306,共8页Journal of Chemical Engineering of Chinese Universities

基  金:河南省重点科技攻关(132102210052)

摘  要:实验研究了泵辅助和无泵辅助板式蒸发器环路热管系统的启动特性、不同热流密度下系统内工质的流动传热特性和热效率,以及在一定热流密度下不同泵功率对泵辅助板式蒸发器环路热管系统的影响。结果表明:无泵辅助系统需蒸发器内产生气态工质后才开始运行并进行换热,冷凝器内的工质是相变换热,而泵辅助环路热管系统一经启动就开始运行并进行热量交换,冷凝器内的换热方式逐渐由显热换热转变到相变换热;无泵辅助系统热效率随蒸发器热流密度的升高而升高,而泵辅助系统随蒸发器热流密度的升高而降低,泵辅助系统整体热效率高于无泵系统;当热流密度为0.25 W·cm^(-2)时,泵辅助环路热管热效率较无泵辅助环路热管热效率高22.1%,而当热流密度为1.25 W·cm^(-2)时,泵辅助系统仅比无泵辅助系统高2.7%,说明当热流密度较小时,泵辅助系统更具优越性;对于泵辅助环路热管系统,系统热效率随着泵功率的增加而减小,在1.25 W·cm^(-2)热流密度下,适用的泵功率强度不应超过0.002 W·cm^(-2),表明系统热流密度与泵功率存在最优匹配。研究结果可为设计分离型平板式太阳能热水器及热沉散热器提供参考。Starting characteristics of plate evaporator loop-heat-pipe systems with/without pump-assistance were studied,and flow heat transfer characteristics and thermal efficiency of the two systems under different heat flux were compared.Effects of different pump power on the pump-assisted system under certain heat flux were investigated.The results show that the non-pump system starts working when the evaporator generates gas working fluids,and the heat transfer in the condenser is via phase change.However,the pump-assisted system starts immediately and the heat transfer mode changes from sensible heat transfer to phase change heat transfer.Thermal efficiency of the non-pump system increases when the evaporator heat flux increases,while the pump-assisted system shows the opposite.The overall thermal efficiency of the pump-assisted system is higher.When the heat flux is0.25W·cm-2,the thermal efficiency of the pump-assisted system is22.1%higher.However,this value is2.7%when the heat flux is1.25W·cm-2.The thermal efficiency of the pump-assisted system declines with the increase of pump power intensity for static heat flux.The pump power intensity should not exceed0.002W·cm-2when the heat flux is1.25W·cm-2,and there is an optimal combination for the system heat flux and the pump power.This study provides guidelines for the design of separate flat-panel solar water heaters and heat sink radiators.

关 键 词:泵辅助环路热管 热流密度 传热特性 热效率 

分 类 号:TK124[动力工程及工程热物理—工程热物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象