摘  要:望远镜光轴与分光计中心轴线垂直的调节是分光计光路调整的重点和难点。针对该问题,通过图解的方式,直观剖析了反射镜正反面反光十字像的位置与载物台和望远镜光轴平行度之间的关系,解决了光路调整过程中反光十字像难找、难调的问题。Adjusting the optical axis of telescope perpendicular to the central axis of spectrometer is crucial in the adjustment of the optical path of the spectrometer.The parallelism between the object stage and the optical axis of telescope has great influence on the position of the two reflection cross images by the front and back of the double-faced reflector.In view of that,the dependence of them has been analyzed graphically to solve the problem that during the optical path adjustment of spectrometer,the two reflection cross images are hard to be adjusted find or even be found.

关 键 词:光路调整 分光计 图解 反光十字像 