检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨达 张浩[1] 蓝惠霞[1,2] 齐有啸 王玮[1] 张恒 YANG Da;ZHANG Hao;LAN Hui-xia;QI You-xiao;WANG Wei;ZHANG Heng(College of Environment and Safety Engineering,Qingdao University of Science & Technology,Qingdao,Shandong Province,266042;Key Laboratory of Pulp and Paper Science and Technology of Ministry of Education,Qilu University of Technology,Ji nan,Shandong Province,250353;College of Marine Science and Biological Engineering,Qingdao University of Science & Technology,Qingdao,Shandong Province,266042)
机构地区:[1]青岛科技大学环境与安全工程学院,山东青岛266042 [2]齐鲁工业大学制浆造纸科学与技术教育部重点实验室,山东济南250353 [3]青岛科技大学海洋科学与生物工程学院,山东青岛266042
出 处:《中国造纸学报》2018年第4期1-6,共6页Transactions of China Pulp and Paper
基 金:制浆造纸科学与技术教育部重点实验室开放基金(KF201509);山东省自然科学基金(ZR2017MC032)
摘 要:以制浆中段废水为研究对象,首先采用正交实验研究了石墨烯促进Fenton氧化的各影响因素间的显著程度,然后通过单因素实验研究了废水pH值、石墨烯加入量以及H_2O_2加入量对废水处理效果的影响。结果表明,石墨烯促进Fenton氧化的各影响因素间的显著程度为废水pH值>石墨烯加入量> H_2O_2加入量> n(Fe2+)∶n(H_2O_2);加入石墨烯后,Fenton反应的最佳pH值由4提高至6;石墨烯最佳加入量为3 mg/L;随着H_2O_2的不断加入,制浆中段废水降解效果先不断升高而后趋于平稳,H_2O_2的最佳加入量为7 mL/L。Fenton反应体系符合一级反应动力学方程,加入石墨烯的Fenton反应速率常数k为0.0632 min-1,比传统Fenton反应速率常数大,表明制浆中段废水的降解速率明显加快。The orthogonal test was used to investigate the significances of the influencing factors in Fenton oxidation treatment of middle stage pulping effluent with the existence of graphene.The results showed that the important degree of various factors was as follows: pH value> graphene dosage> H2O2 dosage> the molar ratio of Fe^2+ to H2O2.Then, effects of pH value, the graphene and H2O2 dosages were studied using single factor test.It showed that the optimum pH value changed from 4 to 6 after the addition of graphene.The optimum grapheme dosage was 3 mg/L.The treatment effect increased continuously and then stabilized with the H2O2 dosage increasing and the H2O2 dosage was preferred to be 7 mL/L.The first-order reaction kinetics equation was conformed for Fenton reaction system.The reaction rate constant k of the Fenton system with the existence of graphene was up to 0.0632 min^-1 , which was larger than that of the traditional Fenton system.The pollutant degradation rate was obviously accelerated by graphene.
关 键 词:石墨烯 FENTON反应 制浆中段废水 CODCR去除率 UV254值
分 类 号:X793[环境科学与工程—环境工程]