作 者:蒋辉 曲金荣 邵楠楠 李祥 孟帆 张宏凯 黎海亮 JIANG Hui;QU Jin-rong;SHAO Nan-nan(Department of Radiology,Affiliated Cancer Hospital of Zhenghzou University,Zhengzhou 450008,China)
机构地区:[1]郑州大学附属肿瘤医院/河南省肿瘤医院放射科,郑州453000
出 处:《放射学实践》2019年第1期26-29,共4页Radiologic Practice
摘 要:目的:比较分析Look-Locker和B1修正变量翻转角(B1-corrected VFA)成像技术获得的正常乳腺腺体及胸壁肌肉的T1弛豫时间。方法:对77例正常乳房分别行Look-Locker和B1-corrected VFA序列扫描获得T1-mapping图像,由两位医师分别测量乳房腺体、胸壁肌肉的T1值,采用组内相关系数(ICC)对两位医师的测量结果进行一致性分析,并分析两种成像方法的变异度,比较两种成像方法的组织T1值差异。结果:两位医师之间乳腺腺体、胸壁肌肉的look-locker法获得T1值的ICC值分别为0.883、0.818;两位医师之间乳腺腺体、胸壁肌肉B1-corrected VFA法获得T1值的ICC值分别为0.796、0.757,一致性均为非常好。Look-Locker法与B1-corrected VFA法所得两种组织的T1值差异均有统计学意义[腺体组织T1值分别为(1423.42±80.63)和(2042.09±150.18)ms,t=35.14,P<0.05;肌肉组织T1值分别为(1369.79±65.24)和(2044.84±133.07)ms,t=48.53,P<0.05]。腺体组织Look-Locker法和B1-corrected VFA法获得的T1值的变异度分别为0.057和0.074,胸壁肌肉组织两种方法获得的T1值的变异度分别为0.048和0.065。结论:采用Look-Locker和B1-corrected VFA法获取正常乳房结构的T1值可行,可重复性较好;两种方法测量的T1值差异有统计学意义,但各组织的变异度较小,能反映正常乳房腺体、肌肉组织的特性,有可能为临床的进一步研究提供基础。Objective:Comparison of the T1 relaxation time in breast and chest wall muscles acquired by look-locker and B1 corrected variable-flip-angle technique.Methods:Look-locker and B1 corrected sequences were applied on 77 cases with normal breasts,T1-mapping images were obtained.T1 relaxation time of mammary gland and chest wall muscle were measured by 2 radiologists independently.Interclass correlation coefficient(ICC)was used to analyze the consistency of the results measured.The coefficient of variation(CV)of T1 relaxation time in gland and muscle was analyzed and the difference of T1 value obtained by these 2 sequences was also compared.Results:The ICC of T1 value of mammary gland and chest wall muscle obtained by Look-locker measured by the 2 radiologists was 0.883 and 0.818 respectively,which obtained by B1-corrected VFA was 0.796 and 0.757 respectively,with excellent consistency.Significant differences were found in T1 relax time between two techniques[T1 value of gland:(1423.42±80.63)vs(2042.09±150.18)ms,P<0.05,t=35.14;T1 value of muscle:(1369.79±65.24)vs(2044.84±133.07)ms,P<0.05,t=48.53].CV of T1 relaxation time obtained by Look-Locker and B1-corrected VFA was 0.057,0.074 respectively in gland and 0.048,0.065 respectively in muscle.Conclusion:Using Look-Locker and B1-corrected VFA sequence to obtain T1 values of normal breast structures are feasible and have good repeatability.Significant statistic difference was existed in T1 values obtained by two methods,yet there were low degree variation between different tissues,which can reflect the characteristics of normal mammary glands and muscle tissue,and may provide guidance for further clinical study.
关 键 词:Look-Locker B1修正变量翻转角 乳腺 T1值
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.134.247.168