检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赵荣建[1,2] 周旺 汤敏芳[1,2] 陈贤祥 杜利东 赵湛[1,2] 杨汀[3] 詹庆元[3] 方震 ZHAO Rongjian;ZHOU Wang;TANG Minfang;CHEN Xianxiang;DU Lidong;ZHAO Zhan;YANF Ting;ZHAN Qingyuan;FANG Zhen(State Key Laboratory of Transducer Technology,Institute of Electronics,Chinese Academy of Sciences,Beijing 100190,China;University of Chinese Academy of Sciences,Beijing 100049,China;China-Japan Friendship Hospital,Beijing 100029,China)
机构地区:[1]中国科学院电子学研究所传感技术国家重点实验室,北京100190 [2]中国科学院大学,北京100049 [3]中日友好医院,北京100029
出 处:《电子与信息学报》2019年第2期469-476,共8页Journal of Electronics & Information Technology
基 金:北京市自然科学基金(Z16003);国家重点研发计划(2016YFC1304302)~~
摘 要:针对传统涡轮式肺活量计存在检测精度不高、可靠性差的问题,该文提出一种新颖的四线涡轮式检测方法,研制了一款高精度、高可靠性的慢阻肺监护系统。在硬件上,根据四线涡轮式检测方法设计了四线式呼气采集电路,提高了光路接收分辨率,并通过合理的元器件布置,减少了发光-光敏二极管相互间串扰,提高了系统的可靠性;在软件上,采用线性回归算法对其脉冲计数与分析得到用力肺活量、峰值流速等早期筛查与诊断指标。该系统利用标准Fluke气流分析仪的进行了数据标定,与传统医用涡轮式肺功能仪测试对比:用力肺活量平均相对误差由1.98%降低至1.47%;峰值流速平均相对误差由2.04%降低至1.02%。实验表明,四线涡轮式慢阻肺监护系统的呼气指标比传统慢阻肺系统检测精度更高,可靠性更好,适用于慢阻肺疾病的早期筛查与精准诊断,结合血氧饱和度、呼气末二氧化碳等指标,能实现对慢阻肺患者的医疗监护,特别对于中度和重度慢阻肺患者能起到预警和控制病情的作用。To improve accuracy and reliability of the traditional turbine-vital capacity meter,a novel four-line turbine-detection method is presented for the high precision and high reliability Chronic Obstructive Pulmonary Disease(COPD)monitoring system.On the hardware,a four-line breath signal acquisition circuit is designed following the four-line turbine-type detection method,which improves the resolution of the optical path through reasonable components arrangement.On the software,a linear regression algorithm is used to obtain early screening and diagnostic indicators such as Forced Vital Capacity(FVC),Peak Expiratory Flow(PEF)and so on.The standard Fluke air flow analyzer is used for data calibration,compared with the traditional medical turbine-type lung function meter:FVC average relative error is reduced from 1.98%to 1.47%and PEF average relative error is reduced from 2.04%to 1.02%.It is showed that the expiratory parameters of the four-line turbine-type COPD monitoring system is more accurate and reliable than that of the traditional COPD system which is suitable for early screening and accurate diagnosis of COPD.Combined with pulse oxygen saturation,End-tidal CO2,it can be used to achieve the medical care for COPD and play an important role to early detect and control of disease for moderate or severe COPD patients.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.38