ZGM磨煤机一次风管堵管原因分析及对策  被引量:1

Analysis and Countermeasure of ZGM Coal Mill Primary Air Pipe Blocking Reason

在线阅读下载全文

作  者:李强 LI Qiang(Datang Northeast Electric Power Experiment & Research Institute Co.,Ltd.,Changchun,Jilin 130012,China)

机构地区:[1]大唐东北电力试验研究院有限公司,吉林长春130012

出  处:《东北电力技术》2018年第11期45-46,共2页Northeast Electric Power Technology

摘  要:某电厂采用ZGM磨煤机正压直吹式制粉系统,运行过程中反复出现一次风管堵管现象,严重影响机组的安全运行。经过一次风调平试验验证和停磨检查,发现分离器折向挡板磨损较严重,对分离器折向挡板进行修复后,彻底解决了一次风管堵塞问题。Some power plant uses positive pressure direct blow pulverizing system of ZGM coal mill.Primary air pipe blocking occurs repeatedly during operation which affects seriously unit safety.Through primary air dynamic balance test and the coal mill check,it is found that the separator baffle wears seriously.After repairing separator baffle,the phenomenon of pipe blocking is solved.

关 键 词:一次风管 堵管 分离器 折向挡板 磨损 

分 类 号:TM621.2[电气工程—电力系统及自动化]

 